background image

 GENERAL INFORMATION

To ensure safe and reliable operation, please carefully read this service and installation manual in its entirety before 
installing and / or using this product. Reasonable care and safe methods in according with sound plumbing practices 
should be strictly adhered to. Before installation, refer to and understand all relevant local plumbing and electrical codes.

 

DO NOT THROW AWAY THIS MANUAL.

 Keep it in a safe place so that you may refer to it for periodic service and 

maintenance.

Always disconnect the power before servicing this product. Failure to do so may result in 

serious injury or death. Consult with a qualified electrician if you are unsure of the power 

source or cannot determine whether power has been properly disconnected

•  Risk of electric Shock. Always disconnect power before servicing the pump.
•  Electrical Connections and wiring for a pump installation should only be made by qualified personnel.
•  This equipment is only for use on 115 volt and is equipped with an approved 3-conductor cord and 3-prong, 

grounding-type plug. To reduce the risk of electric shock, be certain that it is connected to a properly grounded, 
grounding type receptacle.

•  DO NOT bypass grounding wires or remove the ground prong from the plug.
•  DO NOT use an extension cord. 
•  NEVER plug this pump into an outlet while standing on a wet surface.
•  NEVER lift this product by the electrical power cord.
•  NEVER attempt to open or service this pump while it is connected to an electrical power supply. 
•  DO NOT pump gasoline or any flammable liquid with this pump. Explosion, fire or serious injury or death may 

result from pumping gasoline or any flammable liquid with this product.

•  DO NOT pump chemicals or corrosive liquids with this pump
•  To reduce risk of electircal shock, fully read and understand the operating and installation instructions 

accompanying this pump BEFORE attempting to install or operate this pump.

•  Know the pump application, limitations, and potential hazards.
•  Release all pressure within system before servicing any component.
•  Drain all water from system before servicing.
•  Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal 

injury and/or property damage.

•  Check hoses for weak or worn condition before each use, making certain that all connections are secure.
•  Periodically inspect sump, pump and system components.
•  Keep free of debris and foreign objects. Perform routine maintenance as required.
•  Provide means of pressure relief for pumps whose discharge line can be shut-off or obstructed.

  Personal Safety:

•  Wear safety glasses at all times when working with pumps.
•  Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment.
•  Keep visitors at a safe distance from work area.
•  Make workshop child-proof – with padlocks, master switches, and by removing starter keys.
•  When wiring an electrically driven pump, follow all electrical and safety codes that apply.

•  DO NOT use this pump in water over 150° F
•  DO NOT modify the pump in any way.
•  DO NOT remove any tags from the pump or the electrical cords. Removal of these tags may void your warranty.

 SAFETY INFORMATION

Summary of Contents for JP250V

Page 1: ... JP233V ...

Page 2: ...ectrical power supply DO NOT pump gasoline or any flammable liquid with this pump Explosion fire or serious injury or death may result from pumping gasoline or any flammable liquid with this product DO NOT pump chemicals or corrosive liquids with this pump To reduce risk of electircal shock fully read and understand the operating and installation instructions accompanying this pump BEFORE attempti...

Page 3: ...e kits may be used for temporary installations 5 Connect the pipe or the discharge hose to the discharge of the pump 6 Install a union or other means of separating the discharge pipe just above the floor to facilitate removal of the pump if necessary A check valve is required and can be installed in place of a union to prevent the backflow of water after each pump cycle 7 Connect additional pipe a...

Page 4: ... etc that might be preventing the impeller from rotating Reminder Make sure pump is disconnected from power source before checking inlet and impeller area PUMP RUNS AND REMOVES WATER BUT DOES NOT SHUT OFF 1 Float is stuck in the on position Check to make sure the float is free to move up and down without obstruction 2 Switch may be defective Consult factory PUMP RUNS BUT DELIVERS VERY LITTLE WATER...

Page 5: ... of power failure of pump failure Minimally a high water alarm should be installed The Sump Pump Check Valve is a critical component in ensuring a reliable pumping system for years to come However Check Valves have a limited life We strongly recommend that you replace the check valve at least once a year If you live in a cold climate where temperature routinely below freezing make sure that your d...

Page 6: ...nty and must request warranty service through the installing dealer as soon as the problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is non transferable Jackel shall not be liable for any consequential incidental or contingent damages whatsoever Jackel recommends using a professional plumber for all installation and repair...

Reviews: