Specification
Power supply
230 V, 50 Hz
Power consumption
1.5 W
Acoustics
8 melodies and/or 110 dB/m alarm siren
Input wireless devices
max. 8 remote controls or detectors
1 control panel JA-60 or JA-65
Class
II according to EN60950
Working frequency
433,92 MHz
Environmental conditions
interior –10 to +40°C
Safety standards
IP40 according to EN 60529, IEC 529
Installation
UC-260 is powered directly from a power outlet. The device should
not be installed close to any metal structures or other objects
obstructing radio signal transmission.
Enrolling of wireless components
1. Press and hold the button on the top of the UC-260.
2. Plug in the UC-260 to an outlet
and hold the button until you hear
2 beeps.
3. Release the button
– The button will begin to flash, indicating it is in
the programming mode.
4. Enrolling of components:
•
Doorbell button
(RC-11, RC-22, RC-28) can be enrolled by
pressing a button on the controller. Multiple pressing of the
controller’s button will allow you to scroll to a desired melody.
•
Detector - chime
mode
(JA-60 detectors) can be enrolled by
inserting batteries into a detector. If you remove the batteries and
insert them again you can scroll to a desired melody (wait for 10
seconds before reinsertion).
•
Control panel – siren mode
(JA-60 or 65) – while in the service
mode of the control panel, enter code 299.
5.
Up to 8 doorbell buttons or detectors can be used with one UC-260.
6. Exit the programming mode
by pressing the UC-260’s button
briefly.
If you enter the programming mode the way above, all enrolled
components will be erased from the memory.
Adding components
If you want to add additional doorbell buttons or detectors or if you
want to select another melody for an existing component, than:
1. Unplug the UC-260 from the outlet
and wait for 5 seconds.
2. Plug it in again.
3. The button will light – press it and hold it down. After hearing a
short beep, release the button.
The flashing button indicates it is
in the programming mode.
4. Enrolling new components
(or selecting another melody):
•
Doorbell button
(RC-11, RC-22, RC-28) can be enrolled by
pressing a button on the controller. Multiple pressing of the
controller’s button will allow you to scroll to a desired melody.
•
Detector - chime
mode
(JA-60 detectors) can be enrolled by
inserting batteries into a detector. If you remove the batteries and
insert them again you can scroll to a desired melody (wait for 10
seconds before reinsertion).
5. Control panel – siren mode
(JA-60 or 65) – while in the service
mode of the control panel, enter code 299.Up to 8 doorbell buttons
or detectors can be used with one UC-260.
6. Exit the programming mode
by pressing the UC-260 button briefly.
Deleting components
Press and hold a button on the UC-260 and plug the UC-260 into
the mains outlet. Two beeps can be heard and all components will be
erased.
Loudness selection
•
The UC-260 must be in its operating mode (plugged in).
•
Press and hold the button down.
•
After 2 sec you will hear a melody with the new loudness selected
•
Release the button.
This way you can toggle between a standard and a quieter one.