JB-150N-HEAD Wireless valve head 

JB-150N-HEAD Wireless valve head 

1 / 2 

MNQ51100 

This product is a wireless bi-directional device of the 

JABLOTRON 100

 series intended for controlling water heat line 

radiator valves or heat line distributors. A valve head enrolled  
in the 

JA-10xK control panel copies selected PG outputs. 

 

A maximum of 16 valve heads can be controlled by the control 
panel.  

This product should be installed by a trained technician with a valid 

Jablotron Alarms installation certificate. 

Installation

 

The wireless valve head (referred to as the valve head) should  

be installed in a dry indoor environment. Installation is done by  
the use of a heat line valve adapter.  

The JA-11xR radio module must be installed in order to make 

the wireless valve heads functional with a JABLOTRON 100 series 
control panel. The valve head must be enrolled in the control panel 
and takes one position.  

 

  

Fig. 1: 1 – indicator; 2 – battery; 3 – safety ring; 4 – adapter; 

 5 – radiator valve

 

Installation procedure

1.  Remove the original valve head. 
2.  Screw a suitable adapter onto the valve. (4). 
3.  Proceed according to the control panel installation manual.  

Basic procedure: 

a.   Go to the 

F-Link

 program, select the required position 

in the 

Devices

 tab and launch enrollment mode  

by clicking on the Enroll option. 

b. 

 Inserting batteries into the valve head will send 

an enrolment signal to the control panel.  

4.  Attach the valve head to the adapter.  
5.  Close the battery cover. 
6.  When the cover is closed, the tamper contact deactivates and 

the valve head starts calibration for the type of valve used. 
The result of calibration is indicated by a flashing indicator. 
1x  Valve detection has been successful. 
3x  Valve detection has been unsuccessful (the valve head 

will attempt to detect the valve two more times within  
3 minutes). If the valve hasn’t been detected after  
the third attempt, make sure that you have selected  
the correct adapter for the particular valve and that  
the valve head has been attached correctly. Repeat  
the calibration process by opening and closing the battery 
cover.

 

Notes

 

The valve head can also be enrolled into the control panel  
by entering its production code in the F-Link software. 
The 

production code is on a sticker (8) placed under 

the battery. All numbers stated under the bar code shall  
be entered (example: 1400-00-0000-0001). 

 

If communication with the control panel is lost, the valve head 
will stay in the position of the last processed command from 
the control panel. Loss of communication is indicated by a lit-up 
yellow indicator.  

 

When communication is restored, the valve head will switch 
according to the current settings. 

Valve head settings 

Open the 

Devices 

tab in the 

F-Link software. 

Use the 

Internal 

settings

 option at the detector’s position to open a dialogue 

window with settings:

 

PG output reaction:

 Activation by one or more control panel PG 

outputs. The valve head will open when at least one of the selected PG 
outputs is active. 

Reverse response: 

This setting inverts the valve head’s reaction  

to a PG output

The valve head will be open when none of the selected 

PG outputs is active.  

Tamper contact:

  

Enabled

 

– 

 An open battery cover is reported as device 

tampering resulting in system alarm. 

Disabled

 –  An open battery cover is reported as fault with  

a delay of two minutes (time to replace the batteries).  

Note:

 Do not enable the “Tamper contact” option if you suppose 

the batteries will be replaced by the user.  

Valve head removal and battery 

replacement 

Low batteries are visually indicated by a red indicator (1) flashing 

twice every 30 seconds or every time the status of the valve head 
changes. The information is then transferred to the control panel.  
If the “Tamper contact” function is disabled then it is not necessary  
to switch the control panel into Service mode before replacing 
the batteries in the valve head 

Strictly use only new batteries of the same type and brand. 

Always replace all batteries at the same time. 

Instructions

1.  Open the battery cover (6) using an auxiliary tool (7).  
2.  Wait until the pressure piston slides inside the valve head (this 

will release the valve head from the valve to make 
installation/disassembly easier). 

3. Remove 

the 

batteries. 

a)   Now when needed it is also possible to remove the valve 

head from the valve (not needed for battery replacement). 
Pull the safety ring away from the centre using a thin tool 
(7) inserted in the recess of the plastic safety ring (3). 

b) 

Remove the valve head from the valve 

 

4. Insert 

new 

batteries 

5.  Close the cover. Calibration will be performed once the cover has 

been closed. See step 6 in the Installation chapter. 

 

Fig. 2

: 6 – battery cover; 7 – auxiliary tool (a screwdriver);  

8 – production number

 

 Valve head re-enrollment 

Enrolling to a different control panel is done by inserting 

the batteries just like during installation. The valve head must not 
be in radio range of the previous control panel.  

Valve head accessories 

The packaging contains an installation adapter for a valve with  

a thread size of M30x1.5 (VA 50) 

If the VA 50 type adapter is not compatible with the valve used, 

the other 4 types of adapters listed below can be ordered additionally  
(5 pieces in the packaging).  

  JB-VA78 – diameter 23mm (Danfoss RA) 

  JB-VA16 – M28x1.5 (Herz, Polytherm (H), KAN-Therm, Thermoval 

or Buderus) 

 JB-VA26 

– 

(Giacomini) 

  JB-VA80 – M30x1.5 (Heimeier, Herb, Ondra, IVAR, Thermoval) 

Reviews: