background image

JA-84P wireless motion detector with built-in camera 

1 / 2 

MHP56105

 

The JA-84P wireless motion detector with built-in camera 

The JA-

84P is a component of Jablotron’s Oasis 80 alarm system. It provides 

human  body  movement  detection  including  visual  alarm  verification.  The 
detector’s camera is equipped with a flash and infrared light to take photos in 
the  dark.  The  camera  is  capable  of  taking  monochromatic  pictures  with  a 
resolution  of  160x128  pixels.  A  sequence  of  4  photos  is  taken  when 
movement is detected. It is stored in the detector’s internal memory and it is 
also  transmitted  wirelessly  to  the  control  panel  to  be  sent  to  an  alarm 
receiving  center  and/or  to  the  owner’s  mobile  phone  display.  The  battery-
powered detector communicates via the OASIS radio protocol. 

 

 

 

 

Recommended control panel configuration 

To  transfer  photos  from  the  protected  premises,  the  control  panel 

should  be  equipped  with  a  suitable  communicator  (model  JA-80Y  = 
GSM/GPRS software version XA61006 or higher or JA-80V = LAN/PSTN 
software  version  XA64004  or  higher)  and  with  the  JA-80Q  data 
processing  modul

e  connected  to  the  communicator’s  internal  bus 

cable.  

The  communicator  allows  programming  of  an  IP  address  to  which  the 

photos  will  be  transferred  (see  the JA-80Q  installation  manual).  This server 
allows  the  logging  into and  display of the  photos free  of  charge. It  can also 
notify  you  by  SMS  message  when  a  new  photo  arrives,  providing  a  link  to 
view the photo on the phone display. The server can also forward the photos 
to a desired e-mail address.  

Multiple camera detectors 

can be enrolled to the control panel. If more of 

the detectors take photos within a very short period of time, the detectors will 
transfer  the  photos  to  the  control  panel  in  the  same  order  as  the  detectors 
were triggered. 

 

Installation and testing of the motion detector 

Installation  should  only  be  undertaken  by  technicians  holding  a  certificate 

issued  by  an  authorized  distributor.  The  detector  can  be  installed  on  a  flat 
wall  or  in  the  corner  of  a  room.  Avoid  objects  rapidly  changing  in 
temperature, such as electrical heaters, gas appliances etc. being positioned 
within  its  detection area. Moving  objects  with  a  temperature close  to that of 
humans such as curtains moving above a radiator, and pets should also be 
avoided.  Detectors  should  not  face  windows  or  spotlights  or  be  near  fast-
moving air e.g. near ventilation fans or open windows or doors. There should 
also  be  no  obstacles  blocking  the  detector’s  “view”  of  the  protected  area. 
Keep  the  detector  away  from  metal  objects  which  could  interfere  with  radio 
communication. 

 

1. 

Open the detector cover 

by pressing the tab and disconnect the camera’s 

flat cable (pulling the connector placed next to the batteries) 

2. 

Remove the PCB 

which is held by an internal tab. Avoid touching  the PIR 

element 

3. 

Punch  screw  holes  through  the  rear  plastic  cover. 

At  least  one  screw 

should  penetrate  the  tamper-sensitive  section  (be  careful  not  to  break  the 
tamper sensitive section out).   

4. 

Screw  the  rear  cover  to  the  wall, 

about  2.0 

– 2.5 meters above the floor 

(vertically, with the tab down).  

5. 

Replace the PCB 

to its original position. 

6. 

Leave  the  battery  disconnected  and  the  cover  open 

(camera 

disconnected) and then follow the control panel manual to enroll the detector. 
The basics of enrollment are: 
a) 

Enter  enrollment  mode  on  the  control  panel  by  pressing  “1”  while  in 
Service mode. 

b)  Install batteries into the detector to activate enrollment. 

If  the  detector’s  batteries  have  already  been  connected,  first  disconnect 
them,  press  and  release  the  tamper  switch  and  then  reconnect  the 
batteries  

c) 

Exit enrollment mode by pressing “#”  

d)  Leave the control panel in SERVICE mode.  
e)  The detector can be used without a control panel - see stand alone mode. 

7. 

Connect the camera cable and close the detector’s cover. 

If the red LED 

is permanently lit, it means that the motion detector is warming up (it usually 

takes  about  100  sec.  after  the  batteries  are  connected).  If  the  red  LED  is 
flashing, the detector has not been enrolled yet (see point 6). 

8. 

After the red LED turns off 

test the motion sensor by walking in the covered 

area  (detected  movement  is  indicated  by  red  LED  flashes).  Also  test  the 
detector’s radio signal strength – see the control panel installation manual for 
details.  Testing  is  only  possible  within  15  minutes  of  closing  the  detector’s 
cover. After this period the red LED is switched off.  

9.  If the detector is not in test mode, it ignores frequent movements (see sleep 

time chapter).  

10. To observe EN 50131-2-2 the tab must be secured by the supplied screw.  
NOTE: Installation height according to INCERT T014A is 2.0 to 2.4 m. 

 

Detector DIP switches 

C

R

1

2

3

C

R

1

2

3

1

 

2

 

3

 

4

O

N

motion 
sensor

tamper

DIP
switches

camera

PIR

USB plug

release tap

 

 
 

There are 4 DIP switches to select the desired features: 

 

OFF 

delay reaction 

(exit & entrance delay provided) 

ON = instant reaction (no exit & entrance delay) 

This switch onl

y has an effect if the detector’s address has a 

NATUR reaction programmed in the control panel  

OFF 

standard immunity 

for the motion sensor

  

 

ON = increased immunity for the motion sensor (slower reaction)  

OFF = flash disabled (except for testing) 

ON 

flash enabled 

(second to fourth shots with flash) 

Note: The IR light works independently of the DIP 3 setting 

OFF = photos stored only in the camera (not transmitted)  

ON 

= photos stored 

in the camera memory and also 

transmitted wirelessly 

to the control panel

 

Bold 

= factory default setting

 

 

Motion detector coverage 

The  detection  characteristics  of  the  PIR  detector  lens  does  not  affect  the 

detector‘s camera components. The PIR lens covers an angle of 50° and a 
distance of 12 metres.  The area is covered by three beams as shown in the 
following diagram. The horizontal camera capture angle is 50° and the range 
of the flash is up to 3 meters around the detector. 

Top view

PIR

CAMERA

Side view

2,5

Side view

2,5

 

Reviews: