JA-190X Telephone PSTN communication module
JA-190X Telephone PSTN communication module
1 / 2
MMD51102
The JA-190X telephone communicator is a component of the
JABLOTRON JA-100 system. A control panel with a JA-190X
reports voice alarm messages, communicates with ARCs and
provides remote access to the system over PSTN line. The
communicator uses tone dialling only. The module is equipped with
basic overvoltage protection. The product should be installed by a
trained technician with a valid certificate issued by an authorised
distributor.
Installation
Module installation has to be done when the power is completely
disconnected. Insert the module into the right connector on a JA -
10xK control panel PCB.
Figure: 1 – yellow fault indicator; 2 – relay activity red indicator;
3 – telephone relay; 4 – component for overvoltage protection;
5 – terminals for connecting telephone line and grounding
1 The communicator can only be connected to an analogue
telephone line (PSTN).
2 When an ADSL line is used, it is necessary to connect the
communicator after the splitter.
3 The communicator has to be always the first device on the
telephone line, other devices can be connected after it, to the
outgoing terminals labelled OUT.
4 Connect the incoming telephone line (ADSL splitter output) to
the input terminals labelled INa and INb. We recommend
protecting the telephone line against overvoltage.
5 The OUTa and OUTb terminals work as an output for line-end
devices like telephones, fax machines, etc.
6 Do not connect anything to the unlabelled terminal. It is for
other applications.
7 In standby mode all connected devices are ready for use and
the telephone line goes through the telephone line terminals.
When the communicator is being used, all devices connected
to the OUTa and OUTb output terminals are disconnected
during communication.
Voice alarm message reporting
The JA-190X reports voice messages to the preset telephone
numbers. A voice message consists of 4 parts:
Your system r type of section X +
name of the section
Your system reports
=
Premises identification (max. 15s)
Type of report
=
Alarm in instant zone
Alarm in delayed zone
Tamper
alarm
Flood
Fire
alarm
State of emergency
Health
problems
Section X
=
X is the section number
(from 1 to 6 or from 1 to 15)
Section name
=
user defined section name (max. 15s); default:
no name
Remote access to the system by
telephone line
According to the control panel settings by F-Link software, i.e.
the Communication / Voice menu and control SMS tabs, when
calling the system from an arbitrary / authorised telephone the
system will answer your call and ask you to enter your valid code.
The communicator offers options by voice. The structure of the
voice menu changes according to the restriction level of the entered
code. If a new event in the system occurs, the call will be
terminated.
Voice message recording
The language of pre-recorded messages is set by the F-Link
software in the
Initial setup
tab during system installation. Voice
recordings can be made by remote access to the communicator
with Service or Master restriction levels. Do it in a silent room with
no noise. If you do it from your cell phone, check the GSM signal
where you will do the recording, it has to be very strong and stable.
When the connection is established, the communicator starts the
voice menu. Option 9 is “Voice message recording”, and you
activate it by pressing the 9 button. Record messages according to
the commands in the voice menu in the below order
(the maximum
message time is in brackets)
. The beginning of recording is
indicated by one long beep. Messages which can only be recorded
with
Service
level authorisation are marked in
Bold
. The rest of
them are available to Administrator level restrictions.
Press:
0 – ”For premises name recording press 0“
(15 s.)
1 – “For section name recording press 1“
(5 s.).
After pressing
button “1“ you will be offered a recording for every single
section according to the settings in the
Initial setup
tab.
2 – “For special report A press 2”
3 – “For special report B press 3”
4 – “For special report C press 4”
5 – “For special report D press 5”
9 – “To erase all recorded messages, press 9”
# – “To return to the main voice menu, press #“
When the message is recorded it will be repeated by the system
once. And if the message is not satisfactory, you can record it again
by pressing a particular button.
PSTN communicator settings
(Public Switched Telephone Network)
The communicator is programmed by F-Link software – by the
Communication
tab, and the
PSTN settings
button. In the dialog
window you can set:
(default settings are marked*
):
PSTN module:
*Disabled / Enabled
– turn on or turn off the
communication by the JA-190X.
Call limit min. /day:
Limited time for outgoing calls from 5 to 500
minutes / day, (* 20 min).
Remote control by phone:
management of system remote
control by voice menu:
No
: remote access is denied, only outgoing
communication is allowed;
Users:
remote access is allowed only
for users for whom telephone numbers have been set. In the
Communication
tab it is also possible to set access to the voice
menu without entering an access code, see the
Voice menu and
SMS control
option;
Anybody *
: remote access is allowed for any
telephone, but a valid user access code is always requested.
Note: For correct remote access functioning, it is absolutely
necessary to have caller ID display (CLIP) activated, which is valid
for all authorised users.
DTMF tone level (to ARCs): this setting depends on the local
quality of the telephone line and the sensitivity of the ARC input.
Proper functioning (correct settings) has to be checked with the
ARC technicians.
DTMF detection sensitivity (from ARC):
the required setting for
the detection sensitivity
depends on the quality of the local
telephone line and the level of the ARC tone output. Proper
functioning (correct settings) has to be checked with the ARC
technicians.
Note:
Default DTMF detection sensitivity settings are set according to
the norms for PSTN networks. Only use different settings when you
are solving some particular problems and when there are problems
with the telephone line.
PSTN access prefix: (* default: empty)
A sequence dialled
before dialling a telephone number by PSTN. Use it when the
communicator is connected via a private telephone exchange. The
prefix has to be entered to connect to the PSTN before the desired
number is dialled and is set according to exchange requirements.
Detection of dial tone: Enabled*
, The communicator starts
dialling a preset tel. number after the dial tone is detected. If a dial
tone is not detected, the communicator stops its activity and
records the message that hasn’t been delivered in the event log.