The JA-164J One-way four-button keyfob

The JA-164J One-way four button keyfob

1 / 2

MMJ58104

The JA-164J is a component of the 

JABLOTRON 100

system. It uses one 

way communication. It is designed to 
remotely control a security system, 
various appliances (using PG 
programmable outputs PG) or to trigger 
panic alarms. The remote control can 
also be enrolled to multipurpose relays 
such as the AC-16x series for direct
relay control according to the pre-set 
mode. The remote is equipped with 
optical and acoustic indication. It checks 
its battery status and indicates when the 
battery is nearly discharged.

Figure:

1 – LED indication; A, B, C, D – buttons, see their functions according to 

table 1.

Enrolling the remote control to a control 

panel

There must be a JA-11xR radio module installed in the control panel 

for the ability to work with a control panel. The remote can be enrolled 
to an arbitrary number of JABLOTRON 100 systems and one pair of 
buttons can control multiple sections in the system (common control).
It occupies one position in the system.

1. Control panel has to be in service mode.
2. Basic procedure:

a. Go to the 

F-Link

software, select the required position in the 

Devices

tab and launch 

enrollment

mode.

b. For the transmission of an enrollment signal press and hold buttons 

(A+B) simultaneously for at least 3 s (within this time the red LED 
flashes rapidly).

c. After 3 s the enrollment signal is sent and confirmed by one long 

LED flash. Release both buttons and close enrollment mode.

To set the keyfob to comply with security 

grade 2 use F-Link SW, Parameters tab and 
the option “Perform EN50131-1”. (See the 
JA-10xK control panel installation manual)

Notes:

Enrolling the remote control to the system is possible by entering 
the production code via F-Link software. The production code is on
the sticker with a bar code glued onto the battery holder inside the 
remote. All digits in the production code are required

(1400-00-0000-0001).

If you want to remove the remote control from the system (for 
instance when someone has lost it), erase it from the particular 
address of the control panel.

Setting the properties

Perform settings using 

F-Link

software –

Devices

tab. Click on the 

JA-164J´s 

Internal settings

. Then a window appears automatically 

where you can set the following parameters:

Functions of the buttons:

set a particular function for the pair of 

buttons A-B or C-D (setting / unsetting typically, ON / OFF switching of 
some appliance, etc.) or a function for each single button A, B, C, D 
(gate opening, garage door opening, etc.) and a double press of the 
A+B or C+D buttons, i.e. the next button on the remote. For an option 
overview see table 1.

Reaction for single buttons

/

/

/

(A/B/C/D)

Reaction for pressing 

simultaneously

+

/

+

(A+B/C+D)

x

None (button not used)

x

Copy PG

x

Change PG state

x

Silent panic **)

x

Audible panic **)

x

Health troubles

x

Report A, B, C, D

x

None (button not used)

x

Copy PG *)

x

Change PG state

x

Silent panic **)

x

Audible panic **)

x

Health troubles

x

Report A, B, C, D

Reaction for pair of buttons (segment function)

-

/

-

(A-B/C-D)

x

Unset / Set

x

Unset / Partially set

x

Unset / Partially set / Set

x

PG OFF / PG ON

Table: 1. Button function options overview

For each function selected for a remote control button it is necessary 

to select the appropriate PG or sections to be controlled or from which 
reports should be sent (panic, etc.). For the common control of multiple 
sections it 

is not recommended

to operate a common section, but to 

select the desired section in the remote control internal settings.

Notes:

*) The 

„Copy PG“ 

reaction to a double press can be used for a 1 s

impulse only for the selected PG – double button pressing cannot 
send a 1s activation signal repeatedly unlike single buttons.

**) The reactions of the buttons which are not supported when the 

system is configured to comply with security grade 2.

The option “

Do not set with active zone“, 

doesn´t allow the system 

to be set using a remote control (keyfob) when any zone with an 

Instant

reaction is active. To set the system all zones / detectors 

have to be in standby

When the button on the remote control is pressed permanently 
(valid for the “Copy PG“ function) activation is sent continuously 
every 1 s. The function can be used for the extension of the impulse 
of a PG output (the chosen PG output has to be set to the function 
“Copy“). The maximum length of keeping up the activation is 
1 minute

Take over a user´s access privileges:

Take over a user’s access 

privileges for the sections and time limited access according to the 
specific user.

Take over a user’s identity:

The selected user will be visible as 

a source in the event log.

Operation with a multipurpose relay (MPR)

The remote control can also be enrolled to a multipurpose relay of the 

AC-16x series, to control a relay according to the chosen mode. Each 
button should be enrolled to the MPR with a different mode. Even one 
remote can be enrolled to multiple MPRs for example with a different 
function. When you enroll a keyfob to the control panel and also to an
MPR within its RF range, don´t select the same buttons. To enroll 
a keyfob to an MPR, follow the installation manual of the MPR.

Locking the keyfob

The remote control buttons can be locked (blocked) against 

accidental pressing. Locking is disabled by default, pressing any button 
triggers its function immediately. If the buttons are locked, a control 
panel command is sent when a button is pressed 2x quickly (2x per 1 s) 
it is also valid for the panic function.

The 

lock can be activated

by pressing and holding the pair of 

buttons (A+B) at the same time. After pressing both buttons the red 
LED (1) flashes 1x and subsequently after 3 s the red LED starts 
flashing quickly, during LED flashing release button B and then press it 
again. Activation of the lock function is performed and confirmed by 
double flashes of the red LED and a double beep. After this 
confirmation release all buttons.

The 

lock is deactivated

by repeating the procedure above. 

Deactivation of locking is confirmed by one flash of the red LED and 
one beep.

Caution: When a reaction for pressing buttons (A+B) 

simultaneously is set (for example a panic alarm or garage 
door control), it is necessary to mind that the action is 
performed first.

Acoustic indication

Acoustic indication can be completely disabled. The default is 

enabled. When any button is pressed it is followed by a short acoustic 
signal according to the table 2.

The 

acoustic indication

can be disabled by simultaneous pressing 

and holding the pair of buttons (A+B) until the red LED (1) starts 
flashing briefly for the second time, usually in 6 s. When the red LED (1) 
flashes a second time release the button (B) and press it again. The 
acoustic indication is then disabled and confirmed by flashes of the red
LED and a one beep. After this confirmation release all buttons.

The 

acoustic indication

can be enabled by repeating the procedure 

above. Activation is confirmed by a double flash of the red LED and a 
double beep.

Caution: When a reaction for pressing buttons (A+B) 

simultaneously is set (for example a panic alarm or garage door 
control), it is necessary to mind that the action is performed first.

Reviews: