jablotron JA-153E Manual Download Page 1

The JA-153E Wireless access module with RFID and keypad 

The 

JA-153E

  wireless access module with RFID 

and keypad

  is a 

component of the 

JABLOTRON

 

100

 

system. Its modular architecture 

enables users to create a combination whose size of installation 

perfectly meets their needs. The device should be installed by a trained 

technician with a valid certificate issued by an authorised distributor. 

The wireless access module with RFID chip card / tag reader and 

keypad comprises the first control segment (1). JA-192E segments can 

be used to extend the JA-153E unit by the required number of 

segments (the max. allowed amount is 20 on one unit). The keypad 

cover can be removed if the user prefers for full access. 

 

 

Figure: 1 – control segment; 2 – segment buttons; 3 – backlit activation 

button; 4 – access module with RFID card reader;  

5 – tabs for module opening; 6 – keypad cover screws 

 

Figure: 7 – control segment connector; 8 – production code; 9 – terminals; 

10 – mini USB connector; 11 - batteries; 12 – tamper contact 

Installation 

1.  Press the four tabs (5) on the sides (see 1st figure) one by one 

and release the keypad from the plastic base. 

2.  When installing more control segments, first remove the socket 

cover on the 1

st

 segment.  

3.  Remove the plastic windows from the segments (by levering on 

both sides of the segment near the buttons).  

4.  Always connect the segment wires to the connector of the 

previous segment and click them into each other (we recommend 

coiling the wires by turning the segment by 360° - this will prevent 

any possible damage to the wires between the plastic parts). Use 

this method to install all the required control segments. Finally 

push the socket cover in. 

5.  Insert two 1.5V alkaline AA batteries into the keypad. 

6.  Attach the base onto the selected place together with the 

segments using screws. If multiple control segments are 

required attach them onto the wall using screws as well (use 

the number of screws required). 

7.  Connect the segment wires to the internal connector of the 

keypad (7).  

8.  Insert the keypad into the base.  

9.  Proceed according to the control panel installation manual. 

Basic procedure: 

a.  There must be a JA-110R radio module installed in the 

control panel.  

b.  When batteries are inserted, the yellow LED starts to light 

permanently which indicates that the keypad has not been 

enrolled to the system yet. 

c.  Go to the 

F-Link

  software, select the required position in 

the 

Devices

  window and launch enrollment mode by 

clicking on the 

Enroll

 option.  

d.  Press the backlit activation button (3) – the keypad is thus 

enrolled and the yellow LED indicator goes off. (This can 

take a few sec.). An enrollment signal can also be sent by 

inserting the batteries.  

10.  When you have completed installation, insert descriptive labels 

behind the segment plastic windows and close them. Label 

printing is a part of the F-Link software (

Devices

 window, at the 

keypad position – 

Internal settings

), or you can use the label 

printer. 

Note:  

Enrolling the module to the system is possible by entering the production 

code (11) via F-Link software or by a production code reader. All digits under 

the production code are required (1400-00-0000-0001). 

 

Click!

ABCD...123

Click!

2

3

1

4

 

Figure: Insertion of a label into a control segment 

Setting the properties 

Go to the 

Devices

 window in the F-Link software. When you are at 

the keypad position, use the 

Internal settings

 option. The particular 

unit is displayed and it is possible to set its properties. It is possible to 

assign the required functions to individual segments (controlling of 

sections, section status signalling, alarm triggering, PG output 

control, PG output status signalling, etc.). More details are available 

in the F-Link software. 

A common segment (up to 2 of them allowed on one keyboard) 

simulates the simultaneous pressing of several segments which are 

placed on this keyboard and which control sections. The selection of 

sections which are assigned to the common segment is performed by 

F-Link SW, the Devices window. At the keyboard position select 

Internal settings / and Common segment 1 (2) and mark the segments 

which will be operated en bloc. The selected sections will be set / unset 

after pressing a button on the common segment. If the states of the 

segments which are operated by the common segment are mixed, then 

only the segments that need changing will be set  /  unset. If partial 

setting is enabled for some segments, then the common segment 

respects this: 1 st. press = partially setting, 2nd press = full setting. It is 

not suitable to combine a common segment with a common section 

The indication of the common segment is: all segments set = green, 

some set (partially set) = yellow, all sections fully set = red. 

Automatically shutting down the module 

The module saves its energy by shutting down the optical 

indication of system status, keypad backlight and RFID reader 10 

sec. after its last activity with a user. The keypad still keeps 

communication with the control panel and it can signal for example: 

an entrance delay. Complete waking up is done when you press 

the cover of the keypad, otherwise by activation of the magnetic 

door contact connected to the IN terminal (see next paragraph). 

When the parameter „

Entrance delay time and alarm are 

triggering the keypad

“ (default) is enabled, the keypad is also fully 

woken up when these events occur. 

Disabling this parameter gives you a longer battery life time. In 

this case the keypad cannot wake itself and will not indicate the 

system status optically, and acoustic signalling can be delayed a 

few sec. 

 The JA-153E Wireless access module with RFID and keypad 

1 / 2 

MLU51704 

 

Reviews: