JA-151A Wireless external siren 

The JA-151A is a component of the 

JABLOTRON 100

 system.  

It is used for system alarm indication outside a building and as  
a pre-sensing tamper detector. It can also be used for 
supplementary acoustic signalling (PG activation, arming, chirps). 
The siren is equipped with a backup battery which powers the siren 
when the main power is disconnected. The JA-151A includes only 
the base with the 

JA-151A BASE

 PCB and always has to be 

completed with the cover from the 

JA-1X1A-C-xx

 series. The siren 

should be installed by a trained technician with a valid certificate 
issued by an authorized distributor. 

For combinations of colour and cover material see the following table: 

Cover type 

Colour and cover 

material 

Strobe colour 

JA-1X1A-C-GR

 

Grey plastic 

Red 

 

JA-1X1A-C-ST

 

Stainless steel sheet 

JA-1X1A-C-WH

 

White plastic 

JA-1X1A-C-GR-B 

Grey plastic 

Blue 

JA-1X1-C-ST-B 

Stainless steel sheet 

JA-1X1A-C-WH-B 

White plastic 

 

Installation 

The siren should be installed on a vertical wall, with the flasher 

facing downwards. Avoid installing the siren near the gutters and on 
other places where there is a danger of ice accumulation.

  

 

Fig: 1 – hole for installing; 2 – piezo sounders; 3 – NiCd battery with reusable 

battery strap; 4 – hole for cable; 5 – 12V DC power cable; 6 – PCB; 7 – spirit 

level; 8 – hole for installation with tamper detection; 9 – front cover screw;  

10 – string with clip connecting the front cover for easy installation 

 

1.  Push the power cable (5) through the hole (4) in the bottom part 

and secure it using the plastic tabs. 

2.  Attach the siren onto a suitable place using 2 screws through the 

holes (1) and (8). The spirit level can be used for easy 
installation (7). 

 

3.  Connect the backup battery to the connector (13). 
4.  Connect the mains power cable to the terminals (11).  
5.  Proceed according to the control panel installation manual. 

Basic procedure: 
a.  There must be a JA-110R radio module installed in in the 

control panel. 

b.  When the power supply is connected, the yellow LED (14) 

starts flashing to indicate that the siren has not been 
enrolled into the system. 

c. 

Go to the 

F-Link

 software, select the required position in the 

Devices

 tab and launch the enrolment mode by clicking on 

the 

Enroll

 

option.

 

d. 

Press the button marked LEARN (15) – the siren is thus 
enrolled and the yellow LED indicator goes off.

 

6.  Put back the siren cover and attach it using the screw (9). 

 

 

Fig 2: 11- 12V DC power terminals; 12 – piezo siren connection (attention: high 

voltage); 13 – backup battery connection; 14 – yellow fault indicator;  

15 – LEARN (enrolment) button; 16 – external antenna connection;  

17 – external antenna jumper; 18 – high intensity red LED flashers;  

19 – production code 

 

Internal settings of the siren 

The siren properties can be set in the 

Devices

 window of the F-link 

software. When at the siren position, use the 

Internal settings

 option 

to open a dialog window where you can set: (default settings are 
marked *): 

Sections: 

to set for which sections the siren should indicate an 

alarm, as well as setting the chirps. 

The default setting is 

indication for all sections.  

Reaction: defines whether the siren should indicate 

EW*

 

(external warning) or 

IW

 (internal warning); Alarm indication can also 

be disabled completely (other functions remain enabled). 

LED indication: Red* / Blue. 

 According to the siren cover you 

can choose the colour of the LED indicators. 

Siren sound: 

interrupted

*, 

uninterrupted.

 

Alarm indication length: 

1, 2, 3*, 4, 5

 

minutes. 

 

Chirps during section control 

YES / NO*

 

if enabled, the siren 

chirps once upon setting and twice upon unsetting and three times 
upon unsetting after an alarm. The signalling only works for the 
preset sections. 

Siren flashing options: During alarms

 */ (flashes) 

30 minutes 

after an alarm.

 Extended flashing can be terminated by new system 

setting or cancellation of alarm indication in the system (with a 
keypad). 

Flashes every 60 seconds: 

YES / NO*

 

optional indication of 

siren functioning.

 

 

 

PG output activity indication 

The siren can indicate the activity of selected PG outputs with its 

chirps. 

 

Chirp 1

 – slow chirping - 1 per second (for the whole period when 

the PG is active) 

Chirp 2

 – rapid chirping - 2 per second (for the whole period when 

the PG is active) 

Chirp 3

 - 1 chirp when the PG is activated, 2 chirps when the PG 

is deactivated  

Chirp 4

 – a long 20 sec chirp when the PG is activated 

Sound priorities  

The siren sound has the highest priority, the control chirps have a 

lower priority and the PG output activity indication has the lowest 
priority (PG1 has a higher priority than PG2 etc). A chirp with a 
higher priority always terminates a chirp with a lower priority. 

Note:

 Acoustic power depends on battery charge level. 

 

External antenna use 

To improve the communication quality between the control panel 

and the outdoor siren you can connect an external antenna (AN-80, 
AN-81). Plug the antenna into the connector (16) on the PCB. When 
an antenna is plugged in, disconnect the jumper (17).  