JA-11A RB BUS external siren

 

JA-11A RB BUS external siren 

1 / 1 

MLQ54101 

The JA-11A  RB  is a component of the 

JA-10

  system. It is used for 

system alarm indication outside a building and as a pre-sensing tamper 

detector.  It can also be used for supplementary acoustic signalling.  

The siren is equipped with a backup battery which  powers the siren 

during tamper alarm reporting when the connection to the digital bus  

is severed. The  JA-11A  RB  is  completed  by assembling two parts,  

the 

JA-11A-BASE-RB

 base with the PCB and the 

JA-1XA-C-WH

 cover. 

The siren occupies one position in the system. 

Installation 

The siren should 

 

be installed on a vertical 

wall, with the flasher 

facing down-wards. 

Avoid installing the siren 

near the gutters  and  on 

other places where there 

is a danger of ice 

accumulation.  

Figure: 1 – mounting hole; 

2 –  two piezzo sirens;  

3 – NiCd battery with   

      reusable battery strap;  

4 – hole for cable;  

5 – bus-cable; 6 – PCB;  

7 – spirit level;  

8 – mounting hole with      

      tamper detection;  

9 – front cover screw;  

10 – string with clip  

  connecting the front  

  cover for easy   

  installation 

1. Open the external siren cover by releasing the screw (9).
2. Push the bus cable (5) through the hole (4) in the bottom part and 

secure it using the plastic tabs. 

3.  Attach the siren to a suitable place using 2 screws through the holes

(1) and (8). The spirit level can be used for easy installation (7). 

When connecting the siren to the system 

bus, always switch the power off.

 

Figure: 11 – bus terminals; 12 – LEARN (enrollment) button; 13 – tamper 

sensors; 14 – production code; 15  – high-intensity red LED flashers;  

16 – yellow fault indicator; 17 – backup battery connection;  

18 – piezo siren connection (attention: high voltage) 

4. Connect the bus cable to the terminals (11).
5. Connect the backup battery to the connector (17).
6. Proceed according to the control panel installation manual.

Basic procedure:

a. When the siren is  switched on, the yellow LED (16)

indicates that the siren has not been enrolled into the

system.

b. Go to the 

N-Link

  software, select the required position

in the 

Devices

  tab  and launch the enrollment mode by

clicking on the 

Enroll

 option.

c. Press the enrollment button (12)  –  the siren is thus

enrolled and the yellow LED indicator goes off.

7. Put back the siren cover and attach it using the screw (9).
8. 

The siren can be tested by N-Link software by clicking the Test

button  in the internal settings option. After clicking the button the

siren sounds for three minutes and after that flashes for one

minute.

 Internal settings of the siren 

The siren properties can be set in the 

Devices

  window  of the 

N-Link

  program. When at the siren position, use the 

Internal

settings

  option  to open a dialog window where you can set:

(default settings are marked *):

Setting tab: 

Acoustic indication of alarms  from sections: 

to set for which 

sections the siren should indicate an alarm, as well as setting chirps. 

The default setting is indication for all sections.  

Reaction: 

defines whether the siren should indicate

 EW*

 (external 

warning) or 

IW

 (internal warning); Alarm indication can also be disabled 

completely (other functions remain enabled). 

Siren sound: intermittent*, continuous.

 

Maximum siren time: No, 1, 2, 3*, 4, 5

 

minutes. 

Option ‘No’ – the 

siren doesn’t indicate alarm acoustically (optical indication remains) 

During section control: YES / NO* 

if enabled, the siren chirps once 

upon setting and twice upon unsetting and three times upon unsetting 

after an alarm. The signalling only works for the preset sections. 

Optical indication 

Flashes every 60 seconds: YES / NO*

 optional indication of siren 

functioning.

 

After alarm expiration: During alarms, until  memory erased,  

30 minutes after an alarm

  -  the optical indication can be extended 

until  the alarm indication is terminated (by new system setting/ 

unsetting) or the extended time can be set to 30 minutes after the alarm 

expiration. 

Signalling PG tab: 

The siren can indicate PG output activity with its chirps.  

The siren can indicate the activity of selected PG outputs with its 

beeps. 

Slow beeping

  - 1 per second (for the whole period when the PG  

is active) 

Quick beeping

 - 2 per second (for the whole period when the PG  

is active) 

1xOn/2xOff

 - 1 chirp when the PG is activated, 2 chirps when the PG  

is deactivated  

20 seconds of beeping

 – a long 20 s beep when the PG is activated 

Sound priorities 

The siren sound has the highest priority, the control chirps have a 

lower priority and the PG output activity indication has the lowest priority 

(PG1 has a higher priority than PG2 etc). The chirp with a higher priority 

always terminates the chirp with a lower priority. 

Loss of communication with the control 

panel 

If the power supply wire is severed, the siren keeps sounding and 

flashing for 3 minutes (this function does not work in service mode). If the 

system power supply is disconnected due to a discharged control panel 

battery (long lasting power failure) then the siren does not sound and 

flash. 

Backup battery replacement 

The  system reports a low battery automatically. The control  panel 

must  be in service mode before you start changing the battery 

otherwise a tamper alarm will be triggered. Use a BAT-4V8 battery 

only. 