User manual
MLJ57205 - EN user manual - desky.indd 1
20.9.2014 12:23:18
Page 1: ...User manual...
Page 2: ...17 2 2 2 7 Section control from the keypad s menu 17 2 3 Operating the system with a keyfob 17 2 4 Operating the system using a computer and a USB cable J Link 18 2 5 Operating the system using the v...
Page 3: ...LCD keypad 23 5 2 Using the J Link software and a computer 23 5 3 Logging into MyJABLOTRON web smartphone 23 6 WHAT IS THE MyJABLOTRON WEB INTERFACE 24 7 PERIODICAL MAINTENANCE 24 8 TECHNICAL SPECIFI...
Page 4: ...is changed Note Depending on the con guration of the installation and system settings some of the options described below may not be available Consult the con guration of the installation with your se...
Page 5: ...sections Users can change their codes provided that the system uses Codes with pre xes Selected users may have their access to sections limited by a schedule The number of User codes is limited only...
Page 6: ...horization Control panel parameters 4 DIGITS 6 DIGITS 8 DIGITS Using Code with a pre x 104 10 000 106 1 000 000 108 100 000 000 Code with a pre x and Duress access control both disabled 104 Number of...
Page 7: ...FAULT Flashes yellow UNSUCCESSFUL SETTING Continuous green UNSET OFF Flashes green ENTRY DELAY 2 2 USING THE SYSTEM KEYPAD 2 2 1 USING THE SEGMENT KEYPADS JABLOTRON 100 system may be controlled by a...
Page 8: ...of the system using segments and user authorization using contactless method RFID card tag Keypad with a card reader the user can control the system using segments and authorization either by entering...
Page 9: ...Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control panel con guration Displays a list of a...
Page 10: ...delay parameter is enabled then mere authorization will unset such section where the entrance delayed has been triggered Consult the installation with a service technician in order to program the des...
Page 11: ...only while motion detectors inside a house do not react to anything To set the entire premises in which partial setting is enabled the button to set the system has to be pressed twice After the button...
Page 12: ...rst select a particular action by pressing a segment button and then con rm it by authorization using the keypad Terminating an alarm using a remote control will also unset the corresponding section 2...
Page 13: ...artially Unset a RED Set Authorization can be done by entering an access code on the keypad or using an RFID card tag assigned to a particular user Each user can have one code and one RFID chip a card...
Page 14: ...n is activated in the control panel con guration Bypassed detectors Displays a list of all blocked detectors in sections to which a user has access rights Faults in system Displays a list of all detec...
Page 15: ...y has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator ashing yellow reported to the ARC and indicated by an external siren applies to the securi...
Page 16: ...rm when somebody moves inside the section 1 When you enter the building triggering a detector with a Delayed zone reaction the system starts indicating an entrance delay with a continuous tone the sys...
Page 17: ...nd the function button rapidly ashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly ashing red function button indicates the ala...
Page 18: ...The closed lock icon sets programmed sections the opened lock icon unsets them Correct command execution is con rmed by an LED light unsetting green setting red A communication fault out of the contr...
Page 19: ...ntrolled via PC it doesn t check for triggered devices while setting This may lead to setting with a triggered device Be careful when you control the system this way 2 5 OPERATING THE SYSTEM USING THE...
Page 20: ...ser with Administrator rights owner This user has the right to share a whole building or its selected parts single sections PG outputs photo veri cation and measuring devices with other users whose My...
Page 21: ...he shutters on your windows It is also possible to con gure the system not to require a code before a command In such case the command is simply automatically identi ed when the system recognizes the...
Page 22: ...15 seconds SMS message Sending an SMS can switch on off a particular PG Authorization is isn t demanded based on the system con guration Example CODE_CONFIGURED TEXT _ character space MyJABLOTRON web...
Page 23: ...ervice technician can change the security codes The system administrator can make changes from both the LCD keypad menu the J Link software and MyJABLOTRON smartphone app 4 2 CHANGING DELETING OR ADDI...
Page 24: ...nts setting unsetting alarms faults messages sent to users and ARCs in the micro SD card in the system s control panel Each entry includes the date time start and end and source cause origin of the ev...
Page 25: ...se through them in the Photo gallery tab or directly in Recent events a Monitor current temperature or energy consumption including a history overview on graphic charts a And other useful features a I...
Page 26: ...h lead gel 12 V 7 to 18 Ah lead gel Maximum battery charging time 72 h 72 h Max number of devices 50 120 LAN communicator Ethernet interface only LAN version Ethernet interface Dimensions mm 258 x 214...
Page 27: ...sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Outputs PG The security system...