Chimney connector installation
The chimney connector is a set of single wall flue pipes and
elbow installed between the stove collar and the chimney collar.
The single wall chimney connector is sold into any hardware
store and are not approved nor certified. Some rules must be
followed to install it and can be found in the installation codes for
wood heater.
The stove was designed and tested with a
single wall
chimney connector with heat shield.
1. Single wall chimney connector
For the single wall chimney connector, it must be 6 inches
diameter and minimum thickness of 22 gauge 0.029 inches
(0.85 mm).
Install a metal heat shield, 1 inches (25.4 mm)
offset for the single wall section and elbow.
ATTENTION:
−
If heat shield is not present you must move away the
stove to keep 18 inches (45.7 cm) clearance
between combustibles materials and the chimney
connector.
−
Any horizontal section must have a 1/4 inches (6.35
mm) by feet (30 cm) slope toward the chimney collar.
−
Clearance between roof and horizontal single wall
chimney connector must be 18 inch (45.7 cm) or
more.
ALL SECTION AND ELBOW MUST BE CLEAN AND
IN GOOD CONDITION AND MUST BE APPROVED
FOR A CORDWOOD FUEL.
Chimney connector assembly installation
1.
Make a summary installation of all sections and elbows
(if necessary) to ensure that you meet the clearances and
inclinations of the horizontal sections and verify if you
have all the necessary parts for the final installation.
o
For direct vertical installation, you will need:
•
1 vertical section of 24 inches or more;
•
1 adequate length of telescopic chimney
connector section allowing you to connect the
last chimney connector to the chimney collar.
Note
:
Additional section can be used for higher roof.
o
For horizontal run installation you will need:
•
1 adequate length of vertical section
•
1 x 90° elbow or 2 x 45°elbow.
•
1 x adequate length of telescopic chimney
connector section.
Note
:
For better draft performance, two 45 degrees
elbow are preferable, with or without straight section
in between.
2. Disassemble the whole thing and restart screwing the
pieces from the stove to the roof chimney collar
3. Insert entirely the rolled end into the stove collar and
screwing
it
with
a
minimum
of
3
screws
.
4. Install all the next section up to the roof chimney
support and screw every chimney connector parts with
3 screws
WARNING: It is mandatory to screw the pipe to the
stove collar and also at each joints with a minimum
of 3 screws.
5.
Install all the next section and screw it to the
chimney collar.
DO NOT CONNECT CONECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
CONNECTOR PIPES SHOULD NEVER PASS THROUGH
THE CEILING, THROUGH A WALL, IN A CLOSET, IN AN
ATTIC OR OTHER ENCLOSED AREA THAT COULD
CAUSE HEAT BUILDUP. IF YOU NEED TO PASS
THROUGH COMBUSTIBLE MATERIAL, MAKE SURE
THAT
YOUR
INSTALLATION
COMPLIES
WITH
CAN/CSA-B365.
Summary of Contents for PIONEER
Page 4: ...PR_I017 2023 01 23 EN 4 RATING PLATE...
Page 5: ...PR_I017 2023 01 23 EN 5 APPLIANCE DIMENSION...
Page 6: ...PR_I017 2023 01 23 EN 6...
Page 7: ...PR_I017 2023 01 23 EN 7...
Page 34: ...PR_I017 2023 01 23 EN 34 ANNEX 1 Exploded diagram of door Arc door...
Page 35: ...PR_I017 2023 01 23 EN 35 ANNEX 2 Fans electric wiring diagram...