Description of functions
4.5 Default
configuration
The CANlink II is supplied with the following standard configuration:
; this is a configuration file for IXXAT CANlink II
[General]
ProductName = CANlink II
; !Do not change this!
TemplateVersion = 1.0
; !Do not change this!
OperationMode = COPlink
; CANlink and COPlink are possible
; Timeout defines time COPlink waits for new data
at the RS232
; without sending incomplete data block via CAN
Timeout = 100
; 0-65000 (0-6500 ms).
[User]
ConfigAlias = "IXXAT default"
[RS232] ; Parameters of serial communication
RS232baudrate = 9600
; 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200 bit/s
Databits = 8
; 7,8
Parity = no
; no, odd, even
Handshake = no
; no, software, hardware
[CANlink]
; CAN bus baudrate can be defined via CiA value or alternatively
; per registers BTR0 and BTR1 as BTR0/BTR1 (see table below)
; Baud Rate CiA value BTR0/BTR1
; 1 Mb/s 1000 0x00/0x14
; 800 kb/s 800 0x00/0x16
; 500 kb/s 500 0x00/0x1C
; 250 kb/s 250 0x01/0x1C
; 125 kb/s 125 0x03/0x1C
; 100 kb/s 100 0x04/0x1C
; 50 kb/s 50 0x09/0x1C
; 20 kb/s 20 0x18/0x1C
; 10 kb/s 20 0x31/0x1C
CANbaudrate = 100
FrameFormat = std ; std (11 bit ID) or ext (29 bit ID)
ReceiveID = 0x100
SendID = 0x101
Copyright IXXAT Automation GmbH
CANlink II - Manual, V1.3
27