All appliances must be mounted so that the lowest 
point is at least 2.3 m above the floor. The Vent body 
and ducted blower is designed to fit a ceiling cavity or 
between – floor space with a minimum height of 245 
mm. The modules may be installed between joists 
using the spring clips (Fig. 2c). Ensure that the outlet of 
the Vent unit is directed towards the outer wall. If the 
desired orientation of the Vent unit directs the ducting 
across ceiling joists ensure that the closest ceiling joist 
is not within 150 mm of the Vent outlet.

Note:

 Neo Heat Modules (models 36111 & 36112) 

must be located at least 1m away from the nearest 
wall.

Sufficient air inlet into room

Steam will only be removed if there is sufficient flow of 
air through the room. Ensure generous inlets exist 
through windows, vents or under the door. Air flow 
path from inlet to fan should ideally pass over the 
steam sources (see Fig.1).
Bathrooms which have high ceilings, are larger than 
average, or have an open shower may all require 
additional ventilation. We recommend that you visit our 
website for further details and suggestions on 
effectively ventilating your bathroom.

Ventilation Requirements

Clearances

Figure 2a
A

: 215 mm  

B

: 15 mm min. clearance above unit

Figure 2b
C

: Models: 34101, 34102, 35101 & 35102 - 50 mm  

     Models: 36111 & 36112 - 75 mm

D

: Models: 34101, 34102, 35101 & 35102 - 195 mm 

     Models: 36111 & 36112 - 151 mm

E

: Models: 34101, 34102, 35101 & 35102 - 35 mm to 

     structural member
     Models: 36111 & 36112 - 50mm to structural members.

F

: Models: 34101, 34102, 35101 & 35102 - 150 mm.

Figure 2c

Models: 34101, 34102, 35101 & 35102 - 35 mm min.
clearance is required near all joists
Models: 36111 & 36112 - 50 mm min. clearance is 
required near all joists

.

For maximum efficiency and fan performance there 
a few key points to keep in mind when installing your 
Tastic.

are 

Fig. 1: Ideal placement of Ventilation units.
Sufficient air inlets into room are required

Fig. 2b: Minimum clearances for installation

Fig. 2a: Minimum blower clearances

Fig. 2c: Minimum clearances for installation

Overview

Electrical Requirements

Fig. 6: Wiring diagram for models 34101 and 34102, Neo Vent n Lite.

See the wiring diagrams on the following pages for supply requirements and maximum loadings for each 
model. Modules may be connected to a lighting or power circuit if loading permits. These models are for 
wired-in installation and wiring must be carried out by a registered electrician. Switches and a wall plate 
are not provided with the hardwired Neo modules. Do not use this product with any solid state speed 
control or commercial dimming device.

Neo modules are fitted with LED centre lamps. To ensure 

operation and to prolong the life of the LEDs please wire as per 

the following wiring diagrams for the appropriate model.

correct 

Wiring Diagrams

Fig. 8: Wiring diagram for model 36111 and 36112, Neo Heat.

Wiring – Aust & NZ

 

In all versions a local isolating switch (not supplied) 
must be incorporated in the fixed wiring to the 
appliance to allow disconnection of supply during 
maintenance.  This isolating switch, and the wall 
switch, must be located in accordance with Wiring 
Rules AS/NZS 3000. They must not be installed where 
it can be reached from the bath or shower recess or 
enclosure (see AS/NZS 3000 Section 7).

Vent & Vent n Lite models 34101, 34102, 35101 & 
35102: 

Switch the power outlet for the Inline Blower 

with a wall switch (not supplied) as per the Wiring 
Diagrams. Do not mount the power outlet for the Inline 
Blower more than 200 mm from the Inline Blower.

Wiring – UK & Eire

 

In all versions a local isolating switch (not supplied) 
must be incorporated in the fixed wiring to the 
appliance to allow disconnection of supply during 
maintenance.  This isolating switch, and the wall 
switch, must be located in accordance with the 
applicable Wiring Rules and it must not be installed 
where it can be reached from the bath or shower 
recess or enclosure.

Vent and Vent n Lite models 34101, 34102, 35101 
& 35102: 

Supply should be connected to the Inline 

Blower 2-core power lead as per the Wiring Diagrams. 
The plug fitted to the power cord is to be cut off and 
the wires stripped to allow connection.

The colours of the wires in the Inline Blower 2-core 
lead may not correspond to those in the fixed wiring. 
The designation of poles for the Tastic power leads are 
as follows:

 

 

 

 

Tastic Wire 

Colour

Connect to

Supply Pole

Brown

Live

Blue

Neutral

 

Fig. 7: Wiring diagram for model 35101 and 35102, Neo Vent.

E

34101 & 34102: 

0.4A 50Hz

FASCIA

BODY

M

ACTIVE

NEUTRAL

DUCTED FAN

TERMINAL BLOCK

3 X DOWNLIGHTS

ACTIVE

NEUTRAL

FOR SWITCH 

CONNECTION 

REFER TO FIGS 

9 & 11

FOR SWITCH 

CONNECTION 
REFER TO FIG 

10 & 12

35101 & 35102: 

0.3A 50Hz

M

DUCTED FAN

ACTIVE

NEUTRAL

FOR SWITCH 

CONNECTION 

REFER TO FIGS 

10 & 12

36111 & 36112: 

3.3A 50Hz

FASCIA

BODY

ACTIVE

NEUTRAL

TERMINAL BLOCK

THERMAL SWITCH 65°C

HEAT LAMP

FOR SWITCH 

CONNECTION 

REFER TO FIGS 

9 & 11

Wiring Diagrams

* This switch must be double-pole 
with minimum 3 mm contact gap.

type 

A

B

Fig. 3: Layout of Neo Vent and Vent n Lite.

Neo Models: 34101, 34102, 35101 & 35102

Wall switch (not supplied)

Inline Ducted Blower

Ducting

Air outlet grille 

positioned in eaves lining

Exterior
of home

Eaves 

lining

Vent unit

Flexible support

Cable not on 35101 & 35102

Fig. 9

Fig. 10: Inline Ducted Blower

Fig. 11

Fig. 12: Inline Ducted Blower

A

N

E

Wall Switch (not supplied)

A

N

Wall Switch (not supplied)

A

N

E

Wall Switch (not supplied)

A

N

BROWN

BLUE

Wall Switch (not supplied)