background image

The following clearances are 

required, when installing 

the Fresco.

  Installing Fresco

STEP 1

Measure and mark the mounting holes on the ceiling at a distance of 1025mm.  When installing into 

a plaster board ceiling, make sure that the unit is hung from the joists, beams or rafters. This Fresco 

unit is not suitable for recessed mounting.

1025mm

1025mm

1025mm

1025mm

STEP 2 

Screw the fixing caps to the ceiling with the screws provided.

STEP 4 

After the cable is removed from the gripper assembly, measure out the required cable length. The cable length required is calculated by 

the following formula.

Cable length required = Ceiling height – 2.1m  

(e.g. 2.4m – 2.1m = 0.3m of cable required)

When cutting the cable, the cut must be clean so that the end is not frayed which could cause the Cable catching on either the cable 

guides or the gripper assembly.

Note:

 This length is based on the lowest surface for the heater being 2.1 metres from the floor.

Note: 

The lowest point of the heater must be a minimum of 2.1m from the floor.  If this is not done, the installation is not complaint.

Fans, Lights and 

Sprinkler Fittings 

Must Not Be Below 

The Heater

400mm 

min

300mm 

min

2100mm 

min

400mm 

min

1000mm min 

from surfaces  

below heater

FLOOR

CEILING 

<

                   

400mm min

on both ends

For further installation details refer to the Fresco User Guide. 

Installation of any electrical wiring, power outlet or switch is to be carried 

out by registered/licensed electrician and must comply with the current 

Australian/New Zealand Wiring Rules AS/NZS 3000.

Quick set up guide

STEP 3 

To remove the cable from the cable gripper assembly, loosen the clamping nut at the top of the gripper 

and push down. This loosens the lock and the cable is able to move freely through the gripper. When 

the downward pressure is released the gripper will lock onto the cable.

Clamping 

Nut

Gripper 

Assembly

Small 

Thread 

Section

STEP 5 

After the cable is cut and before securing the cable back into the gripper assembly, thread the cable through 

the two cable guides (located on power cord). When threading the cable guide ensure the grub screw is 

loose to allow the cable to pass through easily. NOTE, do not pull the cable back through the grub without 

loosening as this will cause the cable to strip. When the right hight is achieved, tighten and secure the grub 

screw in place.  

Grub 

Screw

Mounting 

Cable

Power 

Cord

Cable 

Guide

STEP 6 

Now thread the mounting Cable through the gripper assembly and use the Clamping Nut to secure 

the Cable in place as shown in the picture from Step 3.  When this is done screw the gripper assembly 

into the Fresco.

Clamping 

Nut

Gripper 

Assembly

Cable 

Guides

STEP 7 

Lift the unit up to the ceiling and screw the fixture attachment to the fixing cap mounted in Step 2.

MODEL No. 23101              

MODEL No. 22001

NOTE: 

Before operating the unit, the instructions and detailed safety cautions must be read. 