GAPS
-
User Guide
E
Settings Examples
E.1
One Transponder
TP
Interr. code
Reply code
TaT
Rep. factor
TP1
1
22
90 ms
x1
Distance max (m)
< 682
< 1432
< 2182
< 2932
< 3682
< 4432
Recurrence
1 s
2 s
3 s
4 s
5 s
6 s
Blanking time TP1
0.8 s
1.8 s
2.8 s
3.8 s
4.8 s
5.8 s
E.2
Two Transponders - Same Interrogation Code
TP
Interr.code
Reply code
TaT
Rep. factor
TP1
1
22
90 ms
x1
TP2
1
23
90 ms
x1
Distance max (m)
< 682
< 1432
< 2182
< 2932
< 3682
< 4432
GAPS recurrence
1 s
2 s
3 s
4 s
5 s
6 s
Blanking time TP1
0.8 s
1.8 s
2.8 s
3.8 s
4.8 s
5.8 s
Blanking time TP2
0.8 s
1.8 s
2.8 s
3.8 s
4.8 s
5.8 s