EN
4.3 Installation & Operation for MIG Welding
4.3.1 Set up installation for MIG Welding
(1)
Insert the earth cable plug into the Negative (-) socket and twist to tighten.
(2)
Plug the MIG welding gun into MIG torch euro-connector on the front panel and tighten
locking nut securely.
(3)
Insert the polarity switch cable plug into the positive socket on the front of the machine and
tighten it.
(4)
Connect the gas regulator to the gas cylinder and connect the gas line to the regulator.
(5)
Connect the gas line to gas connector on the rear panel.
(6)
Connect the power cord of welding machine with the outlet on electrical box.
(7) Place wire onto spool holder - (spool retaining
nut is left hand thread) Feed wire through the inlet
guide tube on to the drive roller.