ADIX-VS General Description - 11
Key Telephone Lamp Indications
Status
Lamp Indication
I-Use (Green) ....................................... Modulation Steady (On)
CO Incoming/Call Forward.................. 0.1 sec. on, 0.9 sec. off
I-Hold (Green) ..................................... 0.5 sec. on, 0.5 sec. modulated on
System Hold/Non-Privacy .................... 0.1 sec. off, 0.3 sec. modulated on
Recall, ICM Incoming, MSG ............... 0.7 sec. off, 0.3 sec. modulated on
DND.................................................... 0.5 sec. on, 0.5 sec. modulated on
Busy..................................................... Steady (On)
Station Port Requirements
Model
Description
Ports Required
IX-12KTS-3....... 12 line keys (24 line keys with IX-12ELK-3) ........... 1
IX-12KTD-3 ...... 12 line keys (24 line keys with IX-12ELK-3) ........... 1
IX-12KTS-2....... 12 line keys (24 line keys with IX-12ELK) .............. 1
IX-12KTD-2 ...... 12 line keys (24 line keys with IX-12ELK) .............. 1
IX-VT................ Versa-Phone ............................................................ 1
IX-MKT ............ Digital Key Telephone............................................. 1
DCKT970 ......... Digital Wireless Telephone...................................... 1
or shared with
digital telephone
IX-DCKT900..... Digital Wireless Telephone...................................... 1
or shared with
digital telephone
IX-DDPH........... Digital Doorphone ................................................... 1
IX-BPAD........... Busy Bypass Unit for IX-12KTx-2 ........................... 1
Time Parameters
Hold Recall Timer................................ 0 - 255 seconds
Timed Trunk Queuing ......................... 1 - 20 minutes
Doorphone Answer Time ..................... 5 - 255 seconds
Hunting Time ...................................... 0 - 255 seconds
Night Mode Start Time ........................ 00:00 - 23:59
Auto CO Answer Start Time ................ 00:00 - 23:59
MISC Relay Timer............................... 10 - 255 ms
System Numbering Plan
ADIX-VS has a Flexible numbering plan. Default numbering is three digits.
Station length can be changed to two, three, or four digits in length.
Summary of Contents for DCKT970
Page 1: ...Owner s Manual SOFTWARE VERSION 7 30...
Page 11: ...Section 1 ADIX VS General Description...
Page 12: ......
Page 38: ...ADIX VS General Description 28...
Page 39: ...Section 2 ADIX VS System Features...
Page 40: ......
Page 54: ...ADIX VS System Features 44...
Page 55: ...Section 3 Digital Telephone User s Guide...
Page 56: ......
Page 120: ...Digital Telephone User s Guide 110...
Page 121: ...Section 4 Attendant Position Features...
Page 122: ......
Page 135: ...Section 5 Single Line Telephone User s Guide...
Page 136: ......
Page 161: ...Section 6 Omega Voice VMI User s Guide...
Page 162: ......
Page 172: ...Omega Voice VMI User s Guide 162...