Aerostat XC Heater 5100550-M Rev 7
21
5.1 Specifications
* Tested in accordance with ANSI/ESD STM3.1-20015.
Note: Discharge times at high speed are approx. 10% longer for 230 V, 50 Hz.
Input Voltage
120 VAC, 60 Hz, 0.6-3.6A (heater on)
230 VAC, 50 Hz, 0.3-1.8A (heater off)
Discharge*
Fan High
Fan Medium
Fan Low
1 ft
2 ft
3 ft
4 ft
5/1.5
5.5/2.5
6.5/4
8.5/5.5 12”/Center
6/1.7
7/3.5
9/5
11/7 12”/Center
8/2
9/5
10/7
12/9 12”/Center
Balance
0 ±10V
Air Volume
Fan low 70 cfm; fan medium 95 cfm; fan high 102 cfm
Air Velocity (fpm)
Fan Low
Fan Medium
Fan High
1 ft
2 ft
3 ft
4 ft
600 300 180 150
800 400 220 180
1000 500 250 200
(measured @ center line of air stream)
Coverage
3' x 6'
Heated Air Temp
Fan High: 4-5°F (2-3°C) above ambient; Fan Medium: 4-5°F (2-3°C) above
ambient; Fan Low: 5-7°F (3-4°C) above ambient, measured at 12" in front
of blower (Heater optional)
Operating Env.
Temperature 50-95°F (10-35°C); humidity 30-70% RH, non-condensing
Ozone
0.005 ppm measured @ 6" in front of unit; test conducted in accordance
with EPA EQOA-0577-019 using Dasibi ozone monitor model 1003AH
Audible Noise
Fan low 52 dB; fan medium 58 dB; fan high 64 dB (measured @ 2’ from unit)
Optional Air Filter
30 ppi open cell polyurethane foam
Enclosure
Formed steel, white polyester paint
Weight
17.5 lbs (7.9 kg)
Dimensions
15-3/8W x 4-1/2H x 8-1/8D in. (39.1 x 11.4 x 20.6 cm)
Warranty
Two year limited warranty
Certifications
230V, 50 Hz
120V, 60 Hz
Summary of Contents for Simco-Ion Aerostat XC
Page 1: ...I O N I Z A T I O N S O L U T I O N S Ionizing Air Blower Aerostat XC User s Manual ...
Page 10: ...Aerostat XC Heater 5100550 M Rev 7 5 2 Installation 2 1 Unpacking 2 2 Location 2 3 Electrical ...
Page 14: ...Aerostat XC Heater 5100550 M Rev 7 9 3 Operation 3 1 Controls Indicators ...
Page 29: ...Aerostat XC Heater 5100550 M Rev 7 24 5 3 Dimensional Drawing ...