Section 2: Installation
Marksman Matrix & Elite
2465-623 User Manual Rev F
Page 8
Inks
Ink is supplied via 500 mL plastic containers. ScanTrue® II PLUS is a pigmented ink formu-
lated for use on porous substrates.
NOTE:
Check the label on the Print Head for correct ink type.
Waste Bottle
The APS includes a Waste Collection Bottle mounted on the rear of the Print Head assem-
bly. This bottle must be changed when full to prevent improper operation of the system.
Instructions for waste disposal are on the collection bottle.
Do not reuse waste ink; contaminants will reduce system lifespan.
Step 3: Mounting the Photosensor and Encoder
Photosensor
The photosensor is both a light source and a sensor. It emits light and detects the arrival of
a product when the product reflects the light source back to the sensor. The sensor then
sends a signal to the controller to start the printing cycle.
The product detect Photosensor should be mounted on either side of the print head so that
the product passes by the sensor before the print face. Remove the plugs or set screws (3/
32" hex head) in the photosensor mounting holes, then attach the Photosensor Mounting
Bracket with the 10-32 x 1/2" screws provided with the bracket.
Encoder
The encoder assembly provides conveyor line
speed information to the controller. It also allows
automatic disabling of printing when the line
stops.
The Marksman© Matrix & Elite System uses a
5000 ppr open collector output encoder. The
wheel is sized to provide the correct timing
inputs to allow the print heads to print from 150
to 300 dpi.
ENCODER ASSEMBLY