Section 2: Installation
Marksman Matrix & Elite
2465-623 User Manual Rev F
Page 6
Setting Up the Print Head
The Matrix/Classic Series print heads are mounted using the 10-32 tapped holes on the
right or left side of the Ink System bottom case. The print head angle can be set between 0°
and 90°. (See “FJSOP4 - Installation of FoxJet High Resolution AMS/APS Printheads” on
page 97 for additional information.)
To adjust the head to its correct angle:
1. Loosen the two set screws (1/8" hex head) on the print head side of the head mount.
2. Rotate the head to the desired angle.
3. Secure the set screws.