20
Integrated Technical Vision Ltd
http://www.itvsystems.com.ua
Press
[1] [#]
(LED1 blinks red, buzzer and LED3 indicate vacant code number, then
LEDs blink synchronously).
Pass a card to reader, after card code read panel proceeds with card settings
editing (LED1 blinks red LED2 blinks yellow alternately). Press
[1] [#]
(LED1 blinks
red LED3 blinks green). Switch on green LEDs 2 and 3 with buttons pressing. Then
press twice
[#]
button to move to higher menu level.
Next
[#]
button pressing switches control panel to the main mode.
40 seconds pause between digits entry causes panel switching to main mode.
Previewing and modifying users codes settings
Press
[2] [#]
and then enter
[code number]
+
[#]
or [code]
[#]
in programming
mode. Now you can edit current code parameters.
Access through access points settings
Press
[1] [#]
being
in code parameters programming mode. Green LEDs will
reflect current parameters settings. If LED2 is on door A access is permitted, if
LED3 is on access is granted through point B.
You can change settings by pressing of
[4]
button - access point A switch on/off,
or
[6]
button - access point B.
[#]
button pressing returns panel to current code
parameters editing. Press
[#]
to move to the highest menu level. Then press
[#]
again in order to exit programming mode.
Direct outputs' management
Press
[1] [#]
being
in code parameters programming mode. LED 2 and 3 reflect
current parameters settings: green LED 2 - relay 1 management, red LED 2 - relay
2, yellow LED 2 - relays 1 and 2, green LED 3 - transistor outputs management.
Programming the panel in stand-alone use
section
action
indication
[1]
Premisses A &B
access rights
[4]
-for access A
green LED2
[6]
- for access B
green LED3
[2]
Outputs
management
[1]
-relay 1
green LED2
yellow LED 2
[2]
-relay2
red LED2
[3]
- transistor output
green LED3
[3]
Not used
[4]
Day/night switch
right
[1]
green LED 2
[5]
Code category
[1]
– 1 category
[2]
– 2 category
green LED 3
[3]
– 3 category
green LED 2
[4]
– 4 category
green LEDs 2
и
3
[#]
Code parametres editing finish
category
status
change permission
access mode
1
not active
prohibited
---------
2
active
permitted
twenty-four-hour
3
active
prohibited
day
4
active
permitted
day