Limited Warranty

Integrated Technical Vision Ltd. warrants that for a period of eighteen months from
the date of purchase, the product shall be free of defect in materials and workman-
ship under normal use and that in fulfilment of any breach of such warranty,
Integrated Technical Vision  Ltd. shall, at its option, repair or replace the defective
equipment upon return of the equipment to its repair depot. This warranty applies
only to defects in parts and workmanship and not damaged incurred in shipping or
handing, or damaged due to causes beyond the control of Integrated Technical
Vision Ltd. such as lightning, excessive voltage, mechanical shock, water damage,
or damage arising out of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be lieu
of any and all other warranties, whether expressed or implied and of all other
obligations or liabilities on the part of Integrated Technical Vision Ltd. This
warranty contains the entire warranty. Integrated Technical Vision Ltd. neither
assumes, nor authorizes any other person purporting to act on its behalf to
modify or to change this warranty, nor to assume for it any warranty or liability
concerning this product.
In no event shall Integrated Technical Vision Ltd. be liable for any direct, indirect
or consequential damages. Loss of anticipated profits, loss of time or any other
losses incurred by the buyer in connection with the purchase, installation or
operation or failure of this product.

Limited Warranty

Summary of Contents for DLK642

Page 1: ...Access Control Panel DLK642 Installation Manual DLK642 A C C E S S C O N T R O L P A N E L ...

Page 2: ...2 Integrated Technical Vision Ltd http www itvsystems com ua ...

Page 3: ...er kind of unauthorised reproduction of this document or a part of it is prohibited Trademarks ITV is a registed trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd provides training in installation programming and utilisation of DLK642 access control panel For detailed information about the training and discussing of our particular requireme...

Page 4: ...stems com ua Contents Preface 5 Features 5 Specifications 5 Terms 7 What s inside 9 Controls and connections on board 11 Control Panel Operation 12 Main Mode 12 Alarm Mode 13 Free Pass Mode 14 Blocked Mode 14 Mounting 15 Wiring 15 Limited Warranty 20 ...

Page 5: ...anagers can retrieve and analyse the information This data provides recording of staff movement within an organization whether it is a small company or a company that employs thousands Features Supports all Wiegand reader technologies Distributed database for independent operation Operates in remote site configurations with dial up requires NDC B052 Card keypad or card and keypad access support On...

Page 6: ...ripple 500 mV 12 V Power consumption Standby current 80 mA 12V Maximal current 130 mA 12V Environmental requirements Operation temperature 0 С 55 С Relative Humidity 80 relative at 35 С Physical dimensions Width 155mm Height 95mm Depth 32mm Weight 0 25 kG Specifications ...

Page 7: ...nvalid code or ID is entered several times succesively Valid code entering clears the counter This function switching on and number of code entrances are subjects of programming Door Contact DC In access control systems various sensors are used to supervise door status opened or closed magnetic door sensor sensor of the turnstile rotor position inductive sensor of car passing through the road barr...

Page 8: ...nt arises RTE button may be used for remote door opening as well Schedules DLK642 is capable to store up to 250 time zones 250 week schedules can be combined from these time zones Moreover DLK642 can store several floating schedules based on a period different to a week The number of such floating schedules depends on period length Several IDs access To enter high security premises presence of mor...

Page 9: ...low Figure1 a General view of DLK642 b DLK642 with front cover off 1 LEDs 2 built in reader 3 backplate 4 panel s PCB 5 PCB of the reader 6 front cover 2 a 1 D1 D0 GN RD Z1 GND ER BZ Z2 GND Z3 Z4 GND Z5 Z6 GND A B GND EB Z7 GND Z8 PW R TM NC1 C1 NO1 NC2 C2 NO2 SA BEL X1 S3 S4 S6 BAT RST S8 S9 X3 DLK 642 VL1 X2 X2 S5 3 4 5 6 б What s inside ...

Page 10: ...Z4 GND Z5 Z6 GND A B GND EB Z7 GND Z8 PW R TM NC1 C1 NO1 NC2 C2 NO2 SA BEL X1 S 3 S4 S 6 BAT RST S8 S9 X3 DLK 64 2 VL1 X2 X2 S5 Panel s PCB PCB of built in reader Bell Locks or strikes PC RS485 Door Contacts RTE s button Free Pass button Door Blocking button M ains Status Power Supply 12 В B a t t e r y S t a t u s External reader What s inside ...

Page 11: ... p m a T 1 C N d e s o l c y l l a m r o N s t c a t n o c 1 y a l e R 1 C n o m m o C 1 O N n e p o y l l a m r o N 2 C N d e s o l c y l l a m r o N s t c a t n o c 2 y a l e R 2 C n o m m o C 2 O N n e p o y l l a m r o N A S V 2 1 t u p t u o r o t s i s n a r T A 3 0 l a n o i t u c e x e f o n o i t c e n n o c r o F s e c i v e d L E B t u p t u o r o t s i s n a r T n e p o A 3 0 n i a r d...

Page 12: ... blocked or free pass Free pass mode has the highest priority as panel switches to this mode in case of fire then blocked alarm and main modes follow Main Mode Panel grants or denies access to cardholders in this mode In Main mode reader s LEDs blink red Access with ID To access the premises cardholder passes identificator to a reader If it is valid a panel grants access unlocks a door and green L...

Page 13: ... If access point is in Alarm state it is prohibited to pass through this point RTE button unlocks a door To switch Alarm mode off pass ID card with Alarm off sign or give a command from PC Alarm Mode In alarm mode reader red LED lights constantly Access point switches into Alarm mode for following reasons In case of door ajar Attempt of access with lost ID If door is opened too long door time expi...

Page 14: ...ng The control panel allows you assigning of Free Pass function to an input for one access point A B or two access points together A B Blocked Mode Blocked Mode is intended for use in situations when access to the premises should be prohibited for everyone in case of security alarm for instance When Access point is in the Blocked mode access is granted only to IDs with Security Service sign Door c...

Page 15: ...er BAT into lower position before programming Set it into upper position for a long term storage and trasportation Wiring Connecting readers DLK642 can control two access points using two readers one is built in reader the other one is external reader They can be readers produced by ITV Ltd or other readers with Wiegand interface X2 terminal block is intended for access point A entrance in case of...

Page 16: ...ght EOL inputs All inputs are programmable see details in Golden Gate manual After reset to factory defaults all inputs become unas signed and not supervised All inputs supervise shortage and break EOL usage is mandatory The following input functions are possible door sensor A B A B RTE button door sensor RTE button free pass A B A B blocking A B A B state monitoring Input normal state is from 1 4...

Page 17: ...mended to use Z7 and Z8 terminals for door sensor connection Free Pass and Blocking An input may be programmed for Free Pass or Blocking If input is programmed for Free Pass DoorA DoorB Free Pass Door A or Free Pass Door B then shortage or opening of this input unlocks correspond ing locking device and personnel can pass freely through the door If input is programmed for Blocking then shortage or ...

Page 18: ...s from damage protect them with diode connected in reverse to current supply of the coil Note the fact that some cheap electric door strikes are not intended for being energized for prolonged time Program relay time as short as possible to avoid door strike coil overheating Sirens Bells and agents There are two additional programmable transistor outputs for siren bell or other agents control Bell ...

Page 19: ...ting Each panel on RS 485 drop line must have the unique address from 0 to 31 To set panel s address proceed as follows 1 Disconnect feeding of the panel 2 Short terminals TM and BEL 3 Supply feeding Buzzer will beep several times and current address settings will be displayed with buzzer beeps and right green LED blinks The digit is displayed as number of beeps and blinks with a pause between dig...

Page 20: ...ical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Integrated Technical Vision Ltd This warranty contains the entire warranty Integrated ...

Reviews: