2. Assembly & Installation
The following items must be checked prior to installation:
• A max. operating pressure of 1000 K Pa (10 bar) must not be exceeded
• The max. ambient temperature is 40° C
• The max. water temperature is 25° C
• The max. flow rate must not be exceeded (see section 2.1.)
• The installation site of the reactor must be frost-protected and dry
2.1. Reactor
The following reactor types are available in the Aquada series:
*
Flow rate: 400 J/m
2
, UV-Transmission: 94 %
Make sure the national standards and prescriptions for assem-
bly and installation are observed. Installation must be carried
out only by qualified technicians.
Type
Length
Diameter
Connections
„
Min. free space
above reactor
Max. flow rate
*
m
3
/h
1
470 mm
70 mm
R 1/2
370 mm
0,70
2
670 mm
70 mm
R 3/4
570 mm
1,77
4
670 mm
101,6 mm
R 3/4
570 mm
3,01
7
1030 mm 101,6 mm
R1
920 mm
6,20
10
1030 mm
140 mm
R1 1/2
920 mm
9,00