370F
370
108
Figure 142: Install and tighten casing jackscrews
6.
Reinstall the shims under the frame foot and tighten the frame foot to the baseplate.
Make sure that you use the proper shim. Mount a dial indicator in order to measure the distance
between the top of the frame and the baseplate. Make sure that the distance does not change as
you tighten the frame-foot bolts.
7.
Check the total clearance of the impeller in the casing.
With new parts, an acceptable range is 0.76 mm | 0.030 in. to 1.65 mm | 0.065 in. If the impeller
clearance is outside of this range, you either have the incorrect parts, an improper installation, or
too much pipe strain. Determine the cause and correct the problem before you proceed.
8.
Adjust the impeller clearance.
Refer to the Impeller clearance setting section for more information.
9.
Replace the auxiliary piping.
10. Fill the pump with the proper lubricant. See Lubricating-oil requirements.
11. Reinstall the coupling guard.
See Install the coupling guard for more information.
NOTICE:
When a cartridge mechanical seal is used, ensure that the set screws in the seal locking ring
are tightened and that the centering clips have been removed prior to startup. This prevents
seal or shaft sleeve damage by ensuring that the seal is properly installed and centered on the
sleeve.
6.6.16 Assembly references
6.6.16.1 Bolt torque values
Table 22: Bolt torque, Nm | lb-ft
This table provides the bolt torque values.
Location
Frame
3196, CV 3196, LF 3196,
3796
NM 3196
3198
Lube
Dry
Lube
Dry
Lube
Dry
Casing bolts (370) or casing
nuts (425)
6-in. STi
Refer to the maximum tor-
que values in Nm | lb-ft for
casing bolts table.
36 | 27
53 | 40
N/A
N/A
8-in. STi
27 | 20
40 | 30
47 | 35
71 | 53
MTi, LTi
36 | 27
53 | 40
47 | 35
71 | 53
6.6 Reassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
147