4.4 Pump-to-driver alignment
Precautions
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
Alignment methods
Three common alignment methods are used:
•
Dial indicator
•
Reverse dial indicator
•
Laser
Follow the instructions from the equipment manufacturer when you use the reverse dial indicator or laser
methods. Detailed instructions for using the dial indicator method are contained in this chapter.
4.4.1 Alignment checks
When to perform alignment checks
You must perform alignment checks under these circumstances:
•
The process temperature changes.
•
The piping changes.
•
The pump has been serviced.
Types of alignment checks
Type of check
When it is used
Initial alignment (cold alignment)
check
Prior to operation when the pump and the driver are at ambient temperature.
Final alignment (hot alignment) check After operation when the pump and the driver are at operating temperature.
Initial alignment (cold alignment) checks
When
Why
Before you grout the baseplate
This ensures that alignment can be accomplished.
After you grout the baseplate
This ensures that no changes have occurred during the grouting process.
After you connect the piping
This ensures that pipe strains have not altered the alignment.
If changes have occurred, you must alter the piping to remove pipe strains
on the pump flanges.
4.4 Pump-to-driver alignment
26
Model 3600 i-FRAME API610 11th Edition / ISO 13709 2nd Edition to current API BB3 Multi-Stage, Axially Split Installa-
tion, Operation, and Maintenance Manual