“Quad II Diaphragm”

Models

4305-144/4325-504 

Automatic Washdown Pump

FEATURES

• Self-Priming
• Dry Running
• Soft, Noise Absorbing Mounts
• Corrosion Resistant Materials
• Meets U.S.C.G. Electric Standards
• Thermally Protected

SPECIFICATIONS

Motor:

Permanent Magnet, Ball Bearings at Front &
Rear Endbell. CE Models are fully
suppressed.

Pump

:

Four chamber positive displacement
diaphragm design; Self-priming up to 6 ft.
suction lift; Pump able to run dry without
damage; Removable port to hose connectors.

With pump intake connected to inlet strainer and supply
tank or through hull fitting and operation switch off, open
outlet valve, then turn pump switch on. Water will begin
to flow, when water is free of air turn valve off. When
valve is shut off pump will stop. Should pump fail to
stop, turn switch off and see the trouble shooting guide.

As a circulation pump, always run full flow with no
restriction. Use 3.5 GPM pump for tanks up to 30

gallons, and use 5.0 GPM pump for tanks up to 50
gallons. Divert excess water, but do not restrict flow.

For portable use we recommend the pump be mounted
on a base (i.e. 3/4” x 8” x 10” board or plywood), add a
length of cable with alligator clips for battery
connection.

OPERATION

Pump Series

Dimensions - Inches (mm)

Weight

Height

Width

Length

lb. (kg)

4305-144

3.75 (95)

6.3 (160)

8.6 (218)

4.5 (2.1)

4325-504

3.75 (95)

6.3 (160)

9.9 (252)

6.0 (2.8)

AMP DRAW

FLOW

PRESSURE SWITCH

PRESSURE

MODEL*

VOLTS

@ 10 psi (0.7 bar)

GPM (l/min)

MAX psi (bar)

STRAINER

NOZZLE

4305-144D

12V dc

5.0

3.5 (13.5)

40 (2.8)

No

No

4305-144L

12V dc

5.0

3.5 (13.5)

40 (2.8)

Yes

Yes

4325-504

12V dc

8.0

5.0 (18.9)

40 (2.8)

No

No

* CE fully suppressed models are identified by a prefix “R” and a CE mark on the label. (i.e. R4305-144).
Self Declaration Of Conformance (SDOC) is available upon request.

Model 4305-144/4325-504

Summary of Contents for Flojet 4305-144D

Page 1: ...turn switch off and see the trouble shooting guide As a circulation pump always run full flow with no restriction Use 3 5 GPM pump for tanks up to 30 gallons and use 5 0 GPM pump for tanks up to 50 gallons Divert excess water but do not restrict flow For portable use we recommend the pump be mounted on a base i e 3 4 x 8 x 10 board or plywood add a length of cable with alligator clips for battery ...

Page 2: ...then pump head mounts while supporting weight of pump STEP 5 Use 3 4 or 5 8 I D flexible hose preferably braided or reinforced Use hose clamps on the slip on barb hose connectors STEP 6 Install a 40 mesh in line strainer in accessible location between tank and pump inlet INSTALLATION STEP I Use 14 gauge stranded wire to 20 12 gauge to 50 from power source STEP 2 Use a 15 amp rated on off switch on...

Page 3: ...ritical to avoid misalignment and subsequent diaphragm damage Upper Housing Check Valve 6 Reassemble upper housing 1 7 Properly seat O Ring in check valve assembly 2 and check if ferrules and screen are in place on upper housing 1 8 Install check valve 2 into upper housing 1 and push in 9 Assemble on to lower housing 4 align 4 screws on to motor by rotating lower housing 4 if necessary to align fe...

Page 4: ...from FLOJET During this one year warranty period FLOJET will at its option at no charge to the customer repair or replace this product if found defective with a new or reconditioned product but not to include costs of removal or installation No product will be accepted for return without a return material authorization num ber All return goods must be shipped with transportation charges prepaid Th...

Reviews: