USER MANUAL 

 

IPC M300 

250019 

 

Internet by coaxial

 

 

 

 

 

 

 

 

 

 

 

V03 

Summary of Contents for 250019

Page 1: ...ITS Partner O B S S L Av Cerdanyola 79 81 Local C 08172 Sant Cugat del Vall s Barcelona Spain Phone 34935839543 info ek plus www ek plus USER MANUAL IPC M300 250019 Internet by coaxial V03...

Page 2: ...9543 info ek plus www ek plus USER MANUAL IPC M300 TABLE OF CONTENTS IPC M300 3 Installation Diagram 3 Connection to the IPC M300 4 Interface 5 EoC Manage 5 Working channel 6 Auto VID 6 CNU list 7 Sla...

Page 3: ...OWER if there is power EOC if the RF chip is correct SYSTEM the system status E1 and E2 displays the traffic status of the DATA IN 1 and 2 MGMT DATA IN X This port enables the internet traffic to proc...

Page 4: ...w 1 Connect to the IPC M300 using a network cable or wirelessly Configure the PC s network adapter using a static IP In order to become easy the configuration EK have the application Ek NET Adapter yo...

Page 5: ...C 08172 Sant Cugat del Vall s Barcelona Spain Phone 34935839543 info ek plus www ek plus 5 USER MANUAL IPC M300 Interface EoC Manage In this menu everything related to the slaves user equipment which...

Page 6: ...IPC M300 Working channel Establishes the method of communication from master to slave If there is a problem when linking the slave with the master no link may be made due to this option If there is a...

Page 7: ...late is configured the enable template option may be selected and then to apply the template to the equipment that is wished to be configured Furthermore if an individual configuration is wished to be...

Page 8: ...C M300 Signal Displays the slave s RF signal levels Edit Enables to identify the slave and its basic information Limits the equipment s overall bandwidth and in the Interface section the desired inter...

Page 9: ...M300 WAN More than one WAN may be added if it is required to make use of additional services otherwise the existing WAN will be modified by establishing as to whether the equipment operates in Bridge...

Page 10: ...ters may be configured Once these changes are completed the changes will be implemented Slave template The general template may be configured here which can be applied to the equipment The previous se...

Page 11: ...om master to slave As its name implies the configuration which will prevail is that of the master over slave From slave to master The configuration which prevails here is that of the slave This mode i...

Page 12: ...stem information Provides information as regards the system identifies the equipment with name and location Save configuration Menu for saving the latest settings Export configuration Exports the mast...

Page 13: ...USER MANUAL IPC M300 Device management The create button enables adding the VLANs that the Master will process If the VLANs are not added and linked to the ports their traffic will not proceed An IP...