Caution
: Do not force the connector ends together. While you hold the
disconnect valve's connector, engage the pit module's connector by rotating
the locking ring until both connectors are securely connected. Twist only the
connector locking ring, not the body of the connector. Twisting the connector
body could damage the pit module and disconnect valve's connector pins.
Install an Itron security seal through the aligned security holes. For more information, see
Attaching a security seal to the completed connection in the Optional Riva Leak Sensor
installation information.
Optional through-the-lid remote antenna installation
Important
: The remote antenna and rod mount adapter are required for all rod and wall
mount installations. For more information, see pit module mounting accessories.
This section provides antenna mounting and connection instructions for modules installed
through a pit lid.
This device has been designed and approved per FCC and ISED rules, to operate with the
antennas listed below. Antennas not included in this list are strictly prohibited for use with
this device. The required antenna impedance is 50 ohms.
To reduce potential radio interference to other users, the antenna type and its gain should
be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that
permitted for successful communication. The optional 900 MHz remote mount antenna
provides increased RF range coverage for the listed mobile applications where the meters
are located deep in a pit boxes.
Installing the OpenWay Riva Water Pit Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
30