Caution:
Always follow your company's procedures for gas meter installation and
operation.
Related Documents
For more information about the Intelis Gas Meter and compatible system architecture
documentation, see your product's documentation. The following table lists documentation that
might be relevant to the setup of your meter. All Itron product documentation can be located and
accessed through
Note:
Where the part number is not specifically listed below, refer to the documentation that
matches your version of the indicated product.
■
Intelis Gas Meter Ordering Guide
(815-0335-00)
■
Intelis Gas Meter Technical Reference Guide
(815-0119-00)
■
Intrinsic Safety Control Drawing for Index Module Replacement of Itron Model Intelis Gas
Meter
(TDC-0978-009)
■
Replacing Batteries in the Itron Intelis Gas Meter
(TDC-978-011)
■
Intelis Gas Meter
Specification Sheet (101584SP)
■
Field Deployment Manager Mobile Application Guide
■
Field Deployment Manager Tools Application Guide
■
Field Deployment Manager Tools Configuration Guide
■
Itron Security Manager User Guide
■
OpenWay Operations Center Collection Manager Device Interface Guide
Specifications
The following table lists the Intelis Gas Meter product specifications.
Specification
Specification value
Meter capacity
250 CFH at ½ w.c. / 7.1 m
3
/h @0.125 kPa
Measurement principle
Ultrasonic time of flight
Accuracy
Class 1 and ±0.5% at room temperature
Meter type
Temperature compensated (TC) or non-temperature compensated (NTC)
Hub center-to-center
6 inches (152.4 mm)
Hub size options
■
10LT
Table 1
Intelis Gas Meter specifications