Itowa Mini RX User Manual Download Page 7

 MINI RECEIVER WITH FIELD BUS 

 

USER MANUAL 

 

 

 

1-1 

1. INTRODUCTION 

The  Mini  Receiver,  which  we  will  call  hereafter  Mini  RX,  has  an  expansion  connector,  CN4,  which 

enables the communication function with a fieldbus module. This module allows establishing links with 

different  types  of  bus,  among  which  are:  PROFIBUS,  CANopen,  DeviceNET,  PROFINET, 

ETHENET/IP and MODBUSTCP. The connection is made through a galvanic isolation and depending 

on the type of bus, a different type of output is available in the equipment. 

This  external  connection  allows  direct  communication  with  a  PLC,  providing  all  the  available 

manoeuvres  in  the  transmitters  both  at  the  digital  level  of  contacts  and  at  the  analog  level  of 

manipulators. In addition to the transmission of commands to the PLC, the equipment incorporates the 

safety relays and allows the auxiliary connection of up to 6 contacts directly to the equipment. 

The  software,  based  on  the  REMOV019a  version,  allows  managing  both  the  configuration  and  the 

communication  with  the  network,  adding  new  functionalities  to  the  receiver,  such  as  the  increase  of 

available  manoeuvres  and  the  use  of  analog  channels  by  copying  the  full  functionality  of  the 

transmitters. 

The device configuration file is provided together with the device: 

  For  PROFIBUS,  the  .gsd  file  is  based  on  the  HMS  industrial  networks  standard  for  DP-V0  in 

slave  mode,  and  will  be  used  later  to  configure  the  device  within  the  network  through  the 

master  device,  usually  a  PLC.  Once  configured,  the  PROFIBUS  master  will  be  able  to  read 

the status of the different digital and analogue commands received from the transmitter. 

  For  PROFINET,  an  .xml  file  is  available  which  is  based  on  the  HMS  Industrial  Networks 

GSDML standard for configuring the slave device on the network. 

  For the rest of field bus devices, the .eds file contains a description of the device, its functions, 

and  the  object  dictionary  description  that  is  implemented.  This  file  is  used  by  the  network 

configuration tools as previously set. 

 

 

 

 

 

 

Summary of Contents for Mini RX

Page 1: ...USER MANUAL MINI RECEIVER WITH FIELD BUS...

Page 2: ......

Page 3: ...IS FORBIDDEN TO FULLY OR PARTIALLY REPRODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY...

Page 4: ......

Page 5: ...3 1 3 1 INTERNAL CONNECTOR 3 1 3 2 EXTERNAL CONNECTOR 3 2 4 SETTING THE SLAVE RECEIVER 4 4 4 1 NODE ADDRESS 4 4 4 2 BAUD RATE 4 4 4 3 I O SETTING 4 5 4 4 BUS TERMINATION 4 6 5 SETTING THE MASTER 5 1 5...

Page 6: ......

Page 7: ...software based on the REMOV019a version allows managing both the configuration and the communication with the network adding new functionalities to the receiver such as the increase of available manoe...

Page 8: ......

Page 9: ...the received information to the master device of the fieldbus The absence of the module is automatically detected by the equipment which waits for its connection to start the normal operation of the e...

Page 10: ......

Page 11: ...at incorporates a female DB9 connector or an RJ45 connector on the base of the housing The External Connection section describes how to connect to the BUS In this case having a non leak proof opening...

Page 12: ...ET diagram Fig 5 DeviceNET connection 3 2 EXTERNAL CONNECTOR A female DB9 connector is available at the base of the housing to connect PROFIBUS and CANopen Or an RJ45 connector for PROFINET ETHERNET I...

Page 13: ...al 1 2 3 B Line 4 RTS 5 GND BUS isolated 6 5 V BUS output isolated 100 mA max 7 8 A Line 9 Housing Shield CANopen PINOUT CANopen DB9M connector Pin Signal 1 2 CAN_L 3 CAN_GND 4 5 CAN_SHIELD 6 CAN_GND...

Page 14: ...rs Fig 8 Possible addresses range from 00 to 99 using each selector as a digit Fig 8 BCD rotary switches In the case of Ethernet bus the address of the module would become 192 168 0 XX where XX corres...

Page 15: ...where the data is stored are page 1 0xA9 Number of digital output channels 0xAA Number of analog output channels 0xAC Number of digital input channels 0xAD Number of analog input channels 0xAE Set to...

Page 16: ...4 4 BUS TERMINATION If you need to use the device as the final line element for the PROFIBUS bus you can activate the end of line impedance by joining the 3 vertical jumpers of the expansion board Fi...

Page 17: ...ed from the configuration interface of the master bus device to identify the equipment and configure their properties In this way the equipment is registered in the network and the master can communic...

Page 18: ...ting Subsequently the programming of the PLC would be performed using the bits of this data input to perform different maneuvers The frame allocation document contains the layout of the data in bytes...

Page 19: ...nt is started and will keep the manoeuvre information updated with every change that is communicated through the radio transmitter When the radio communication is cut off the data will be initialized...

Page 20: ......

Page 21: ...the general refuses avoids possible negative consequences for the environment Furthermore it allows a proper recycling process for all the pieces This implies both energy and resources saving This sym...

Page 22: ......

Reviews: