ITOH DENKI CBM-103FN Manual Download Page 1

 

 

 

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

 

Page 1 of 10 

 

 

www.itohdenki.com

 

ITOH DENKI, USA, INC. 

[email protected]

 

135 Stewart Road 

Ph:  570.820.8811 

Hanover Industrial Estates 

Fx:  570.820.8838 

Hanover Township, PA  18706 

rev13-0514 

CBM-103FN/FP Circuit Board 

 
 

 

 

 
 

Features 

 

  New driver card specifically designed for the new KE series Power 

Moller® family 

  Adjustable acceleration and deceleration time (0 to 2.5s) 

  Stable speed operation 

  Manual or automatic recovery from thermal overload and low voltage 

  One (1) rotary switch to select up to 10 different fixed speeds 

  Two (2) LEDs (green & red) to identify error type 

  Pulse signal output to indicate motor revolution (2 pulses/motor 

revolution) 

  RoHS and EMC conformity 

  Low Voltage Protection 

  External Direction control 

Summary of Contents for CBM-103FN

Page 1: ...iver card specifically designed for the new KE series Power Moller family Adjustable acceleration and deceleration time 0 to 2 5s Stable speed operation Manual or automatic recovery from thermal overload and low voltage One 1 rotary switch to select up to 10 different fixed speeds Two 2 LEDs green red to identify error type Pulse signal output to indicate motor revolution 2 pulses motor revolution...

Page 2: ...utput signals open collector 24V 25mA or less NPN 0V PNP 24V DC selectable for Error only Applicable PM Models PM635KE Brake Dynamic electric Protection Motor control thermal protection 95 C 203 F on the PCB 105 C 221 F in the motor Built in diode for incorrect wiring protection Built in 18A in line fuse for supply protection Built in thermal fuse to prevent overheating 139 C 282 F Applicable Envi...

Page 3: ...Description 1 24V DC 2 0V Wire size 28 14 AWG CN3 7 PIN connector MOTOR Connector on Card JST S7B XH A Connector for Wiring JST XHP 7 PIN Description 1 GND Grey 2 12V DC Blue 3 Hall sensor U Violet 4 Hall sensor V Orange 5 Hall sensor W Green 6 Thermistor Light Blue 7 Not used Wire size 28 22 AWG Terminal pins JST SXH 001T P0 6 CN4 3 PIN connector MOTOR Connector on Card JST S3P VH Connector for W...

Page 4: ...3 105 PIN Description 1 24V DC PNP or 0V NPN input RUN 2 24V DC PNP or 0V NPN input DIR 3 0 10V DC input V IN speed variation 4 24V DC or 0V output ERR 5 0V NPN output PLS pulse Wire size 28 20 AWG Control Wiring Power to CN1 24V DC remains ON control motor Run Stop through CN2 NPN Input Control PNP Input Control Press down spring clamp in connector with a small screwdriver Insert leads in proper ...

Page 5: ...ches User Settings DIP Switch Function ON OFF Initial Setting Manual Reset Auto matic Reset 1 Error recovery Thermal Low voltage Induced voltage See Page 8 ON External Voltage Input Internal Rotary Switch 2 Speed change selection See Page 6 OFF 3 Motor Direction no external DIR signal viewed from cable side CW CCW OFF 4 ERR output Normal ON Error ON OFF OPERATION Potentiometers Potentiometer Funct...

Page 6: ... 6 87 3 23 0 3 3 44 0 25 284 3 74 8 19 7 n a 2 81 0 25 236 9 62 3 16 4 2 2 19 0 25 189 5 49 9 13 1 1 1 56 0 25 142 1 37 4 9 8 0 0 94 0 25 94 8 24 9 6 6 10 speed steps available through on board rotary switch 16 speed steps available through external voltage input V IN n a 0 31 0 25 47 4 12 5 3 3 Motor Pulse Output Signal 0V NPN output from CN2 5 Two 2 pulses per motor revolution Maximum speed puls...

Page 7: ... power Supply power 24V DC Flashes two times with a 1 5s pause Fuse or temperature fuse blown Card must be replaced Normal Flashes Slowly Stalled motor Motor shuts off Flashes Slowly Motor is disconnected at CN4 Motor does not run Flashes Quickly Current limit active May indicate overload during operation Thermal error in motor or on PCB Motor stops after 4s Motor is disconnected at CN3 Motor does...

Page 8: ...tor shuts off Thermal error PCB or motor Motor control circuit has reached 95 C 203 F on the PCB or 105 C 221 F in the motor After operating temperature is restored Low voltage Supply voltage has dropped 15V for at least 1s or dropped 15V five times within 0 5s After supply voltage rises 18V Induced voltage overspeeding Voltage from motor rises 40V After induced voltage drops 30V Turn OFF RUN sign...

Page 9: ...a DC power supply the voltage drop during motor operation across the power bus may be significant may drop below 15V If there is a large enough drop in voltage the roller s may behave in a strange manner In order to prevent this a larger gauge wire must be used Grounding Ensure the control card is securely grounded to the conveyor frame The conveyor frame should also be at the same potential refer...

Page 10: ... Road Ph 570 820 8811 Hanover Industrial Estates Fx 570 820 8838 Hanover Township PA 18706 rev13 0514 Revision History Revision Number Change 11 0914 Initial document 12 1226 Added autosensing inputs and precautions for electrical potential 13 0314 Added diode recommendation and wiring diagram 13 0514 Removed auto sensing feature ...