Itm TES-1316 Instruction Manual Download Page 1

Instruction Manual
TES-1316

Dual Data Logger Thermometer

FR

EN

IT

DE ES

   

  

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for TES-1316

Page 1: ...Instruction Manual TES 1316 Dual Data Logger Thermometer FR EN IT DE ES www com information itm com 1 800 561 8187...

Page 2: ...10 Version No 00 TABLE OF CONTENTS TITLE PAGE 1 INTRODUCTION 1 2 SPECIFICATIONS 2 3 FRONT PANEL DESCRIPTION 4 4 OPERATION INSTRUCTIONS 7 5 MAINTENANCE 13 6 RECALIBRATION PROCEDURE 14 www com informat...

Page 3: ...al temperature scale of 1990 ITS 90 Read the following information carefully before attempting to operate or service the meter When servicing use only specified replacement parts Environment condition...

Page 4: ...9 F S type 2 0 to 1767 0 C 35 to 1999 9 F Display effective resolution J K T E and N type 0 1 C F K R and S type 1 0 C F K 0 1 C F K only for reference Measurement accuracy J K T E and N type 0 05 of...

Page 5: ...ontinuity data logging capacity 4100 sets 2 2 General specifications Power supply Qty 6 AAA batteries Battery life approx 80 hours Auto power off 30 minutes If no key is pressed Low battery indication...

Page 6: ...3 FRONT PANEL DESCRIPTION T1 T2 14 10 12 13 1 5 4 2 3 7 9 8 15 6 11 C D A B 16 TYPE MX AVG MN INTERVAL min sec hour min T2 T1 T1 T2 C F K KJTERSN T1 KJTERSN TYPE hour min min sec INTERVAL T2 MX T1 T2...

Page 7: ...r off 4 MX MN key Press MX MN key to step through the maximum minimum and average readings Press MX MN key for 2 seconds to exit MX MN mode 5 T1 T2 T1 T2 key Press T1 T2 T1 T2 key to toggle between T1...

Page 8: ...ode 10 TYPE key Press TYPE key to select the thermocouple type K J E T R S or N 11 READ key Press READ key to show manual memory logged readings Press again to exit this mode 12 C F K key Press C F K...

Page 9: ...thermometer Plug the thermocouple s into the thermocouple input s as required If no thermocouple is plugged into the selected input or the thermocouple is open circuit the appropriate display will sh...

Page 10: ...n and min sec on the LCD display The elapsed time since entering reading mode or the time at which the MAX MIN or AVG value occurred will appear on the time display Press T1 T2 T1 T2 key to toggle bet...

Page 11: ...sed time T2 Averaging reading plus averaging time TYPE min sec K MX MN AVG C T1 T2 present reading T1 T2 Maximum reading plus elapsed time T1 T2 Minimum reading plus elapsed time T1 T2 Averaging readi...

Page 12: ...in memory will be cleared 4 4 To Trigger One by One Datalogging Press the MEM key once and one set of readings will be stored in memory The LCD display shows MEM and a memory location number 01 to 98...

Page 13: ...splay will show INTERVAL MEM and interval time Press or key until the display shows the required logging interval 3 to 255 seconds and then press key to select Press the MEM key for 2 seconds to start...

Page 14: ...nnot be read using the READ function to show the data the on display 4 6 How to disable auto power off function The meter will automatically turn off if no key press occurs for 30 minutes Press key to...

Page 15: ...with a damp cloth and mild detergent Do not use abrasives or solvents Clean and dry as required 5 2 Battery Replacement When the LCD display shows BT the battery has insufficient power to support an...

Page 16: ...IBRATION PROCEDURE The thermometer should be calibrated once a year to ensure its continued accuracy Contact RS Components for further details of calibration service The address is given at the end of...