10.11
Switch Trace ON/OFF +TRACE
This command controls the trace; it allows selecting the trace mode, method and the trace data transfer rate.
•
Set command switches the trace on or off. It allows the trace mode, method and the trace data transfer
rate.
•
Read command allows seeing the current set mode value along with the speed, i.e. data transfer rate. It
also allows knowing which traceable unit is on or off.
•
Test command returns all the possible values of mode, data transfer rate, traceable unit, their mode and
power saving countdown.
Syntax:
AT+TRACE=[<mode>],[<speed>],[“<unit>=<umode>]”,[“<method>”],[PowerSavingCountdown]
Command
Possible Responses
+TRACE=[<mode>],[<speed>],[“<u
nit>=<umode>]”,
[“<method>”],[PowerSavingCount
down]
+CSIM: <length>,<response>
OK
+CME ERROR: <err>
+TRACE?
+TRACE:<mode>,<speed>, <unit>=<umode>
;..;<unit>=<umode>
“,”<method>”,<PowerSavingCountdown>
OK
+TRACE=?
+TRACE: [list of supported <mode>s],[list of supported
<speed>s],[list of supported “<unit>=<umode>s]”,[list of
supported “<method>”s],list of supported
[PowerSavingCountdown] values.
Defined values
<mode> may be
0
switch trace off
1
switch trace on (all kinds of traces are switched on)
128
This value can not be entered, it is only displayed via read syntax if trace configuration is done
by unit definitions the last time. See <umode> & <unit> for trace configuration;
<speed>
trace data transfer rate which may be
115200 bps
230400 bps
460800 bps