iTegno 39XX GPRS Modem
AT Commands Guide
02000C17
•
v1.5
Confidential
All specifications are correct at the time of release. iWOW Connections owns the proprietary rights to the information contained herein this
document. It may not be edited, copied or circulated without prior written agreement by iWOW Connections Pte Ltd. © 2011, 2012 iWOW
Connections Pte Ltd
144
10.9
Indicator CCIND
Description:
This command sets the supported MT indicators <ind>.
Note: When value=0, indicator is off.
Syntax:
AT+CIND=[<ind>[,<ind>]]
Command
Possible Responses
AT+CIND=[<ind>[,<ind>]]
+CME ERROR: <err>
AT+CIND?
+CIND: <ind>,<ind>
+CME ERROR: <err>
AT+CIND=?
+CIND: (<descr>,(list of supported
<ind>s)) [,(<descr>,(list of supported
<ind>s))[,...]]
+CME ERROR: <err>
AT+CIND=?
+CIND: ("signal", (0-5)), ("smsfull", (0-1))
OK
AT+CIND?
+CIND: 0,0
OK
AT+CIND=1,1
OK
Defined Values
<ind>
Integer Type value with range corresponding to <descr>
<descr> Supported Indication types
“signal”
=
Signal Quality. <ind> range (0 – 5).
“smsfull”
=
Short Message storage is full. <ind> range (0-1)
0
=
Short Message storage memory locations are available
1
=
Short Message storage has become full