6.2 Protections
Protection
Battery Over Voltage
Battery has reached or
exceeded the over-
voltage point
Controller will
automatically stop
charging and
discharging
Battery Over
Discharge
Battery voltage has
dropped below the
Low voltage disconnect
point
Controller will turn off
the load and only
recover once the
battery has charged
above the low voltage
reconnect voltage.
Overload
The connected load
exceeds the rated
current
The load will
automatically be
turned off
6.3 Charging Profiles
NOTE: Values with (E) next to them indicates user adjustable values. For
iTechworld Lithium Batteries, please use LiFePO4(4-3.2) only, please refer to
section 4.4.1.
- 20 -
Re-Bulk
Bulk
Eq
Abs
Flt
LVD
LVR
Usr1
13.0
14.4
14.6
(E)
14.4
(E)
13.8
(E)
10.8
(E)
12.6
(E)
Gel
13.6
14.4
14.2
14.2
13.8
10.8
12.6
Sld
13.6
14.4
14.6
14.4
13.8
10.8
12.6
Fld
13.6
14.4
14.8
14.6
13.8
10.8
12.6
LiFePO4
(4-3.2)
13.0
14.40
14.2
14.4
13.8
11.2
12.8
LiFePO4
(5-3.2)
16.2
18.0
14.2
14.4
13.8
14.0
16.0
LiPo
(3-3.7)
12.0
12.6
14.4
14.4
13.8
9.9
11.1
LiPo
(4-3.7)
16.0
16.8
14.4
14.4
13.8
13.2
14.8
Usr2
13.6(E)
14.4
(E)
14.2
14.2
13.8
10.8
12.6