6.11.1 IO–1. Ps-Clear, Not-Invert
Parameter Description
IO–1. Ps-Clear,
Not-Invert
Parameter setting for pin 1.
Not-
Invert
Indicates whether to invert the input/output
pulse or level signal.
•
Invert: Yes
•
Not-Invert: No
Invert
Ps-
Clear
This default function means that when
the instrument generates protection,
the protection state can be cleared via
this pin.
Input
Pin 1 receives the level signal from
the outside.
Output
Pin 1 sends the digital signal (1, 0,
PWM) to the outside.
True
By default (
Not-Invert
), the
output digital signal is 1 (i.e.
low level), and in the case of
Invert
, the output is high
level.
False
By default (
Not-Invert
), the
output digital signal is 0 (i.e.
high level), and in the case of
Invert
, the output is low level.
PWM
Digital signal of PWM.
PWM Freq
Frequency
PWM Duty
Duty cycle
How to Use
When pin 1 is set to default
Ps-Clear
function, pin 1 has bi-directional I/O func-
tion, which can receive pulse signal input from the external instrument and also
can output pulse signal to external instrument. Pulse signal parameter require-
ments are as follows:
Copyright © Itech Electronic Co., Ltd.
190
Summary of Contents for IT6000B Series
Page 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Page 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Page 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Page 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Page 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...