background image

350/500/650-WATT AMPLIFIER 

T-6500

T-6350

T-6650

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

PUBLIC ADDRESS SYSTEM

ON

OFF

POWER

CLIP

TEMP

VOLUME

PROT

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

SIGNAL

350-WATT AMPLIFIER

T-6350

ON

OFF

POWER

CLIP

TEMP

VOLUME

PROT

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

SIGNAL

500-WATT AMPLIFIER

T-6500

ON

OFF

POWER

CLIP

TEMP

VOLUME

PROT

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

SIGNAL

650-WATT AMPLIFIER

T-6650

Summary of Contents for T-6350

Page 1: ...lso recommend that you keep this manual handyfor future reference PUBLIC ADDRESS SYSTEM ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL 350 WATT AMPLIFIER T 6350 ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL 500 WATT AMPLIFIER T 6500 ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL 650 WATT AMPLIFIER T 6650 ...

Page 2: ...DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 4 3 Rear Panel 24V 8 5 CONNECTIONS 5 1 Speaker Connections 9 5 2 XLR Connections 9 6 APPLICATIONS 10 7 11 8 SPECIFICATIONS 12 9 DIMENSIONAL DIAGRAM 13 BLOCK DIAGRAM ...

Page 3: ...t in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstab...

Page 4: ... in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Loud noise produced at high volume when power is switched on can impair hearing Do not operat...

Page 5: ... from 350W to 500W and 650W 2 100V 70V lconstant voltage outputs and 4 16 ohms constant resistance outputs 3 Commercial grade torroidal transformers produce high performance audio on a wide range of frequencies with minimal noise and high fidelity even at high volume 4 Intelligent limiter can reduce excess signal 5 Reliable protection against overload short circuit and power fluctuation for optimu...

Page 6: ...shut down 2 VOLUME Channel volume control 3 TEMP Temperature Indicator 4 PROT Protection indicator LED Prot lit when over heat short circuit and overloading 5 CLIP Clip lit when max wattage output output signal distortion 6 SIGNAL Signal indicator LED When lit input signal is detected 7 POWER Power Indicator 4 1 T 6350 6500 6650 FRONT PANEL 1 2 3 4 5 6 6 7 ...

Page 7: ...UT 6 35TRS Balanced or unbalanced output music signal unbalanced output use of non equilibrium 6 35TRS jack 13 LINE CASCADE OUTPUT CORLEONE SOCKET XLR output signal of power amplifier 14 FAN Equipment exhaust vents equipment work properly you must wrap the hole can not have any object covered to avoid overheating protection 15 GROUND LIFTER Earth line ground or lift switch Enable the switch to GND...

Page 8: ...unbalanced input use of non equilibrium 6 35TRS jack 13 LINK OUTPUT 6 35TRS Balanced or unbalanced output music signal unbalanced output use of non equilibrium 6 35TRS jack 14 LINE CASCADE OUTPUT CORLEONE SOCKET XLR output signal of power amplifier 15 FAN Equipment exhaust vents equipment work properly you must wrap the hole can not have any object covered to avoid overheating protection 16 GROUND...

Page 9: ...NECTIONS 100V LINE 100V T 6350 T 6500 T 6650 14 9 8 7 5 70V LINE 5 1 SPEAKER CONNECTIONS 4 16 4 16 70V 4 16 T 6350 T 6500 T 6650 28 6 20 15 4 COM 70V 100V 4 16 COM 70V 100V 4 16 COM 70V 5 2 XLR CONNECTIONS 9 ...

Page 10: ... MIC2 MIC3 MUTE EMC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V AMPLIFIER REC LINE 10 LINE 9 LINE 8 LINE 7 LE FT RIGHT MIC INPUTS MIC LINE INPUTS MAX 9 9W P T T 1 2 3 4 5 6 7 8 9 10 INSIDE AC DC FUSE 230VAC DC POWER 24V MAX 0 6A 2 1 3 7 4 52 4 2 GND PRIORITY CHIME LED PWR MIC INPUT 1 3 5 6 7 1 3 6 CHIME REMOTE 2 OUTPUTS 1 MIXER AMPLIFIER SPEAKERS 10 ...

Page 11: ...7 BLOCK DIAGRAM PROTECT Output Level meter 100V 70V 4 16 Ohms COM INPUTS EB EB INPUTS LINK 230V 0V 220 240 50 60Hz 11 ...

Page 12: ...5mV 0dB 50Hz 18KHz Better than 105dB Less than 1 at 1KHz 1 3 rated power Power switch volume control Power clipping Signal protect and high AC fuse short circuit clipping and high temperature DIMENSION mm NET WEIGHT GROSS WEIGHT 484X408X132 POWER CONSUMPTION POWER REQUIREMENTS T 6350 350W 17Kg 14 5Kg 500W 21Kg 18 5Kg 950W T 6500 500W 19Kg 16 5Kg 720W 12 220 240V 50 60Hz ...

Page 13: ... 383 377 132 138 436 484 UNIT mm ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL 13 COM 4 16 70V 100V OUTPUTS COM COM GND LIFT INPUTS LINK INPUTS LINK 1 1 2 2 3 3 XLR BAL 1 GND 2 HOT 3 COLD ...

Page 14: ...7 132 138 436 484 UNIT mm ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL ON OFF POWER CLIP TEMP VOLUME PROT 5 0 1 2 3 4 6 7 8 9 10 SIGNAL 14 GND LIFT INPUTS LINK INPUTS LINK 1 1 2 2 3 3 XLR BAL 1 GND 2 HOT 3 COLD COM 4 16 70V 100V OUTPUTS BATT SUPPLY 24V 30A ...

Page 15: ...PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0 4 ...

Reviews: