background image

 

 

 

IMB223 

Rev.1.00 Oct.

 ‘21

 

 
 
 
 
 
 
 
 
 
 
 

DISPLAY L.P.

 

Digital process display 4 - 20 mA

 

User manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

Summary of Contents for DISPLAY L.P.

Page 1: ...IMB223 Rev 1 00 Oct 21 DISPLAY L P Digital process display 4 20 mA User manual...

Page 2: ...4 3 Specifications 5 4 Functional description 6 5 Installation and operation 7 5 1 Installation 7 5 2 Operating mode 7 5 3 Programming mode 9 6 Maintenance 12 7 Transportation and storage 13 8 Packag...

Page 3: ...operating manual No technical modifications may be made to the device The device may not be used if the environmental conditions temperature humidity etc are not within the limits indicated in the spe...

Page 4: ...e device includes the control and monitoring of industrial processes The display can be used in automated systems as a primary or secondary display The device may only be operated properly installed a...

Page 5: ...20 mA Dynamic input resistance 200 Ohm Accuracy 0 2 1 digit Display LED 7 segment display Character height 14 mm Display colour red or green Number of digits in display 4 Sampling rate without dampin...

Page 6: ...ncreases the speed of pa rameter changing in three steps The operating modes are described in Section 5 The device has the following functions Display physical parameters received from process control...

Page 7: ...e square root calculated if the function is enabled and the signal according ly to the set parameters calibrated and displayed The scale factor is calculated based on the parameter di Lo lower limit a...

Page 8: ...IMB223 Rev 1 00 Oct 21 Installation and operation Fig 3...

Page 9: ...tion on off on oFF Comments 1 Factory settings are highlighted 2 With particular setting parameters the device cannot display the necessary minus sign due to the re striction to four segments The para...

Page 10: ...IMB223 Rev 1 00 Oct 21 Installation and operation Fig 4...

Page 11: ...I This means that the upper end of the menu has been reached If the button is pressed while the parameter Sqrt is being displayed the following characters appear on the display I This means that the...

Page 12: ...ce person nel and comprising the following tasks Removing dust dirt and foreign matter from the housing Checking mounting of device Checking connections The device should be cleaned with a damp cloth...

Page 13: ...tation and storage The device must be transported in closed transport boxes Protective measures against shocks vibrations and humidity must be observed There may be no chemically active substances in...

Page 14: ...IMB223 Rev 1 00 Oct 21 Package content 8 Package content Digital process display 1 Gasket 1 Mounting nut 1 User manual 1...

Page 15: ...IMB223 Rev 1 00 Oct 21 Annex A Dimensions Annex A Dimensions Fig A 1 To prevent the device spinning the borehole in the front panel must correspond to the dimensions in Fig A 2 Fig A 2...

Page 16: ...IMB223 Rev 1 00 Oct 21 Annex B Electrical connection Annex B Electrical connection Fig B 1 Fig B 2...

Page 17: ...r technical and editorial errors or omissions in the material contained herein nor for incidental or consequential damages resulting from the supply performance or use of this material Warranty We war...

Reviews: