BGA Assembly
First check that the pin 1 positions on the pad pattern and all of the components are correctly
aligned.
1. Mount the Solder part on the Target.
2. (optional) Install the Extender after checking for a match with the position of pin 1 for the
Solder part. More Extenders can be added between to gain additional height.
For ordering the correct amount of Extenders go to the
chapter.
3. Connect the Emulation Adapter after checking for a match with the position of pin 1 for the
Extender/Solder part, and connect the Debug Adapter/Active Probe from the BlueBox to the
connector on the Emulation Adapter. For more information on how to connect iSYSTEM
hardware refer to isystem.com/connect.
4. Gently press with you thumb on the Target Microcontroller and with your other hand
carefully align the notch on the Debug Adapter with the orientation key of the connector on the
Emulation Adapter. Press the cable carefully straight down until the latches lock.
To prevent breaking of the hardware setup or just part of it avoid disconnect and connecting
the hardware setup too frequently.
Emulation Adapter with Debug Adapter
Extender (optional)
Solder part
Electronic circuit PCB