DCM600 to 1800 - Instruction Manual
installation and start-uP (end)
oPeration (Cont’d)
adJustMents
Shutdown
Let the dust vacuum particles suspended in the blast room fall down.
Turn off the engine of the dust collector.
Turn off lights extra.
Close the air supply.
Empty the dust of the dust by trapping in the dust collector or empty the dust collection barrel.
See page 17.
Pressure Module
The pressure regulator located at the entrance of the tank, adjust the pressure pulses. Adjust the pressure
to 70 psi.
Automatic cleaning system
Your dust collector is equipped with an automatic cleaning of the cartridges. A digital display will indicate
the status of dirt cartridges, this indication is expressed on a scale of inches of water vacuum, this value
will indicate the restriction (amounts of dust) on the cartridges. when the fan is on the value should be
between 0.1 to 3.9. when the unit has new cartridges that value will be close to 0.1 and as and when the
cartridge is clogged with dust that value will increase. The electronic module will activate the cleaning
cartridges as needed according to the schedule settings and cleaning will stop automatically when the
cleaning is completed. If your dust collector is equipped with a HEPA option please ensure that preventive
maintenance is performed to replace the filters on a regular basis, they could affect the amount of air
cfm circuit and minimize the visibility for the operator blasting cabinet (HEPA system has no automatic
cleaning system
Programming automatic sequencer
This module can be configured to achieve maximum efficiency of your cartridges, some parameters must
be changed if required Please refer to the section: DCT1000 module.
Use the keys (Select) and (Up) (Down) you will be able to change some parameter
Note: Your unit has been programmed in the factory, if you change some settings be sure to write down
the initial settings