Iso-Tech LCR 1705 Instruction Manual Download Page 1

Instruction Manual 
LCR 1705 / 1707 
Smart tweezers LCR Tester 

EN

 

 

LCR 1707

Summary of Contents for LCR 1705

Page 1: ...Instruction Manual LCR 1705 1707 Smart tweezers LCR Tester EN LCR 1707...

Page 2: ...the risk of fire or electric shock do not expose this product to rain or moisture Do not touch any circuits or parts of circuits if there may be 30VAC rms or 30 VDC on them Be careful of the test pro...

Page 3: ...scard this product or throw away See instruction manual Symbols as marked on the Meter and Instruction manual Maintenance Do not attempt to repair this Meter It contains no user serviceable parts Repa...

Page 4: ...es 2 Push buttons for features 3 LCD display 20 000 counts 4 Mini USB plug for charge connect to PC Assembly 1 USB cable 2 AC adaptor for 1707 3 L Type Test probes special screws x 4 for 1707 4 Softwa...

Page 5: ...4 Measuring Principle tan D 1 Q R X X tan C 1 fC 2 1 X L fL 2 X R X X tan X X R Z X j X R E C L 1 C L C L 1 C L 2 C L Series Measuring Parallel Measuring...

Page 6: ...pressed in exponential form representing the complex amplitude magnitude and phase of a sinusoidal function of time When phase 0 Then Z impedance is Capacitive reactance When phase 0 Then Z impedance...

Page 7: ...f WARNING and CAUTION Power On Off Press the central power button to turn on Press and hold the power button 2 sec to turn off Auto Power Off If there is no any action in the meter then the meter will...

Page 8: ...L C R button to enter manual test mode In manual test mode press the AUTO L C R button to select measuring function To return the auto test mode press and hold the AUTO L C R button 2 sec Measuring D...

Page 9: ...calibrate the meter press and hold the Cal Hz button 2 sec about 15 sec OPEn blinks When OPEn appears on the display make the test probes open and press the Cal Hz button to start open calibration Dur...

Page 10: ...utton to start short calibration During short calibration the Srt blinks on the display About 15 seconds later the result of the short calibration appears on the display If the result shows PASS press...

Page 11: ...old mode Relative Press and hold the H button 2 sec to start the relative mode The meter stores the last reading as reference and shows the indication on the display In this mode the meter deducts the...

Page 12: ...n the display Always use the typical mini USB plug adaptor to charge Do not continue to charge more than 8 hours to prevent the battery damage Connect to PC PC PC The meter can connect to PC by USB ca...

Page 13: ...Charge Cycle 2 hours typical Low Battery Voltage 3 8V Auto Power Off Default 10 minutes Operating Ambient 0 C to 30 C 85 RH 30 C to 40 C 75 RH 40 C to 45 C 45 RH Storage Temperature 20 C to 60 C 0 RH...

Page 14: ...basic accuracy that following conditions must be met Ambient temperature 23 C 5 C 80 RH Open and short calibration have been performed D 0 1 for C L measurements Q 0 1 for R measurements Do not measu...

Page 15: ...ance 2 50dgt rolling 3 If D 0 1 the accuracy should be multiplied by 2 1 D Capacitance Range 100Hz 120Hz 1kHz 10kHz 100kHz 200 00pF N A N A 2 0 1pF 1 2 0 1pF 1 2 2000 0pF 0 5 8 1 0 5 8 1 0 5 8 1 0 5 8...

Page 16: ...M 0 5 5 1 0 5 2 N A N A 20 000M 1 0 5 2 N A N A N A 1 Accuracy is specified after subtract of the offset resistance 2 50dgt rolling 3 If Q 0 1 the accuracy should be multiplied by 2 1 Q DC Resistance...

Page 17: ...teration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantabil it...

Page 18: ...nited Kingdom Japan West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan USA 7410 Pebble Drive Fort Worth Texas 76118 6961 Canada 1701 Woodward Drive Ste...