USER’S  MANUAL

Read all precautions and instructions in this manual

before using this equipment 

www.steril-line.com

Cleaning Air T6

Cleaning Air T12

Summary of Contents for Air T12

Page 1: ...ian Spa Beauty and Tanning Equipment contact isoitalia com www isobenessere com www isoitalia com USER S MANUAL Read all precautions and instructions in this manual before using this equipment www steril line com Cleaning Air T6 Cleaning Air T12 ...

Page 2: ...ATION COMMISSIONING OF THE APPLIANCE AS WELL AS OPERATIONS OF EXTRAORDINARY MAINTENANCE AND PERIODIC PRO GRAM CHECKS MUST ONLY BE CARRIED OUT BY TECHNICAL PERSONNEL SUITABLY TRAINED USING ONLY ORIGINAL SPARE PARTS AFTER REMOVING THE PACKAGING ENSURE THE INTEGRITY OF THE PRODUCT If in doubt do not use it and contact the point of sale for a suitable analysis of the problems encountered The manufactu...

Page 3: ...or system out side the provisions of this manual Do not replace the components with non original MATERIALS or in any case not sup plied by the ISO Italia GROUP as they may compromise the correct operation of the appliance DO NOT DAMAGE PUNCTURE CUT OR OPEN ANY COMPONENT THAT IS PART OF THE EQUIPMENT AVOID ANY CONTACT BETWEEN THE EQUIPMENT AND POSSIBLE OPEN FLAMES INCANDESCENT OR BLUNT OBJECTS THAT...

Page 4: ...he presence of people Check lamp operation on each reflecting chamber Anti UVC Light Guide MPI17624 MPI17625 Oven coated steel load bearing structure with epoxy powder HEPA filter on drawn air total filtration H13 H14 180 150 45mm MPI17609 Filter in class F9 in suction alternative to HEPA on request when ordering MPI17607 Weekly programmable timer with a few hours power reserve MPI17602 Internal c...

Page 5: ... 5cm Height 110cm for equipment with floor support Width 29 5cm Depth 22 5cm Height 90cm for wall mounted equipment Weight 20 kg Sterilised air 120 m h approx Average Noise 5 5 60 dB approx Liquid protection IP20 Noise IP Grade Wall mounting reference points NB The floor mount with wheels and rear han dle are optional components provided on re quest ...

Page 6: ... the presence of people Check lamp operation on each reflecting chamber Anti UVC Light Guide MPI17624 MPI17625 Oven coated steel load bearing structure with epoxy powder HEPA filter in suction 2 pcs total filtration H13 H14 180 150 45mm MPI17609 Filter in class F9 in suction alternative to HEPA on request when ordering MPI17607 Weekly programmable timer with a few hours power reserve MPI17602 Inte...

Page 7: ...CAL CHARACTERISTICS Overall dimensions Product dimensions on wheels Width 29 5 cm Depth 45 cm Height 103 cm Weight 38 kg Sterilised air 240 260 m h approx Average Noise 5 5 60 dB approx Liquid protection IP20 Noise IP Grade 12 ...

Page 8: ...eference for compliance with the essential requirements are as follows For safety CEI EN 60335 1 Safety of household and similar electrical appliances Part I For magnetic fields CEI EN 62233 measurement methods for electromagnetic fields of household and similar electrical appliances with reference to human exposure The product covered by this declaration has been marked in accordance with the afo...

Page 9: ... reference for compliance with the essential requirements are as follows For safety CEI EN 60335 1 Safety of household and similar electrical appliances Part I For magnetic fields CEI EN 62233 measurement methods for electromagnetic fields of household and similar electrical appliances with reference to human exposure The product covered by this declaration has been marked in accordance with the a...

Page 10: ...the air in the room 24 hours a day without any risk and any adverse effects for the people present The uninterrupted disinfectant action ensures the continuous control of the bacterial load of the rooms and the safety of keeping the microbial load always under control on the contrary intense but discontinuous disinfection results in a swinging level of germs present in the room Cleaning Air T6 T12...

Page 11: ...es for the destruction of micro organisms see next paragraph the following tables of the times of use for some environments have been defined Treatment times for environments Cleaning air T6 surface environments in m volume environments in m sanitisation time min 16 43 2 23 20 54 28 40 108 57 60 162 85 100 270 142 Treatment times for environments Cleaning air T12 surface environments in m volume e...

Page 12: ...nexpensive and eco friendly as no chemicals are added to air water and there are no hazardous or toxic chemicals to dispose of Benefits of UVC germicidal systems Disinfection times are rapid with a typical disinfection cycle lasting about 15 minutes excluding germicidal air systems This allows extremely fast turnover times for sanitising environments For its simplicity UV C disin fection is extrem...

Page 13: ... ozone layer micro organisms have not developed a natural defence against UV C energy When the DNA of a micro organism absorbs UV C energy molecular instability occurs resulting in interruption of the DNA sequence This makes the cell unable to grow or reproduce Without the ability to reproduce the cell cannot infect and dies quickly The application of UV C energy to inactivate micro organisms is k...

Page 14: ...icial by the end of October However all bacteria and viruses tested to date many hundreds over the years including coronaviruses are eliminated by UV disinfection UVC rays or germicidal range inactive i e kill eliminate at least two other coronaviruses that are the closest relatives of the COVID 19 virus SARS CoV and MERS CoV Large scale preparation of UV inactivated SARS coronavirus virions for v...

Page 15: ...15 ...

Page 16: ...rrent time and for setting time 7 m Time setting key changing minutes for current time and for setting time 8 X Skip soft key pressing this key reverses the set mode of operation For example if the programmer is in ON mode it will shut down immediately and vice versa until the end of the program 9 R Reset key will clear all settings and time of the current day 10 When program selections 1 3 5 7 9 ...

Page 17: ...symbol Shut down will be indicated by an even number in the lower right part of the display without any symbol Caution When programming each switch on point is closely linked to the next switch off point it is important to program them in copy in order to avoid mistakes Programming procedure a Turn the sliding switch 3 to P and the No 1 appears at the bottom right corresponding to the first switch...

Page 18: ...bol is displayed in the Display wait 3 4 seconds 3 Then pressing the Skip X key resets the Skip Function Warnings for Skip Function The number and symbol indication on the Display appear after an interval of 3 seconds The Skip Function intervenes only until the next programmed switching point is reached At this point the Skip Function is can celled and the programmed switching cycles are activated...

Page 19: ...case of transport damage contact the dealer Caution The product uses UV radiation do not use the product in case of direct light filtration from the lamps to the out side DAMAGE TO EYES and SKIN MAY OCCUR THE PRODUCT IS INTENDED FOR INDOOR USE ONLY AND IS NOT SUITABLE FOR WET ENVIRON MENTS TO AVOID THE RISK OF FIRE OR ELECTRIC SHOCK THE APPLIANCE MUST NOT BE USED WHERE CONTACT WITH WATER IS POSSIB...

Page 20: ...ans of the regulator lo cated near the timer programmer in order to optimise the noise perception of the indoor fan in small environments View from below 3 15A fused switch Weekly Scheduler Handle for easy handling tilting the structure backwards the device rests on the wheels thus facilitating movement For packing and transport reasons the handle is supplied separately the fixing with the screws ...

Page 21: ...mechanical characteristics paragraph two at the top and one at the bottom image below right 4 Remove the equipment from the position and make the holes in the wall 5 Attach the mechanical structure to the wall using the anchoring mode screw type and plug most suitable for the wall type 6 Refit the upper finish casing and then the lower one 7 Connect to the mains supply by means of the power cord b...

Page 22: ...AUTION CHECK THAT THE LICENSE PLATE DATA IS COMPATIBLE WITH THOSE OF THE POW ER SUPPLY LINE OR ELSE THE PRODUCT MAY BE DAMAGED After connecting the plug to the outlet of the system operate the switch located in the centre below the equipment on the side of the time programmer in this condition the time programmer switches on and it will then be possible to start a san itisation session of the room...

Page 23: ...ure correct operation depending on the set programmes the power supply must always be on otherwise the settings made may be lost The timer programmer has a power reserve of a few hours for any momentary power shortages In any case during prolonged periods without use it is advisable to disconnect the equipment from the mains CONNECTION TO THE MAINS In order to maintain the sanitising and germicida...

Page 24: ...79 To access the air filter remove the lower casing fixed with two screws on one side and 1 on the other Inside the casing the filter is affixed with 4 steel springs that can be rotated to remove the filter and replace it When insert ing the new filter pay attention to the direction of air flow so as not to compromise its effectiveness Then proceed with the operation in reverse to close everything...

Page 25: ...wo UVC lamps Of course the operations should be repeated on both sides for the Cleaning Air T12 product The lamps are removed by 1 turning the lamp 180 2 pulling the lamp forward as for a normal neon tube so as to remove it from the 2 support feet WARNING the lamps must only be replaced with original components for the type refer to the electrical characteristics paragraph Upper neon holder foot U...

Page 26: ...ep a history of maitenance and assistance and to keep it safe together with the product manual Model equipment maintenance program Serial number Date intervention description materials replaced notes No 01 02 03 04 05 06 07 08 09 10 11 12 13 ...

Page 27: ...27 ...

Page 28: ...28 ...

Page 29: ...iving from industrial processes or agricultural artisan commercial or service activities which in view of their quantity of characteristics are not classified as normal household refuse DEMOLITION AND DISCHARGE OF THE UNIT The unit must be considered as AEE electrical and electronic unit and must be discharge as it is The under reproduced symbol indicates that the unit at the end of its life has t...

Page 30: ...INFORMATION UVC RAYS 12 PROGRAMMABLE TIMER OPERATION DESCRIPTION 16 INSTALLATION 19 GRAPHICAL DESCRIPTION CLEANING AIR T6 20 COMMISSIONING CLEANING AIR T6 19 Version with pedestal 20 Wall version 21 GRAPHICAL DESCRIPTION CLEANING AIR T12 22 CONNECTION TO THE MAINS 23 MAINTENANCE 24 Replacing the air filter 24 Replacing lamps 25 WIRING DIAGRAMS 27 CORRECT WASTE DISPOSAL 29 GENERAL INDEX 30 GENERAL ...