9
Product Version 1.0 | Revision A | Released 2022-2-21
UNPACKING
Unpack the device and inspect it to ensure that it has not been damaged during transport.
The i-2 UVA is shipped with:
•
1 x omega bracket with 1/4-turn fasteners (standard only)
•
1 x mounting bracket with fasteners (standard only)
•
Safety information leaflet
•
2 m IP66 power cable pigtail
APPLICATION CONSIDERATIONS
The standard fixture is IP65-rated and is designed for both indoor and outdoor events. This means that it is protected
from:
•
Dust, to the degree that dust cannot enter the fixture in sufficient quantities as to interfere with its operation.
•
High pressure water jets of water from any direction.
When selecting a location for the device, ensure that:
•
It is situated away from public thoroughfares and protected from contact with people.
•
It has adequate ventilation.
• It is not immersed in water.
When using standard fixtures outdoors or in wet locations, ensure that:
•
The DMX out of the last fixture is properly sealed, in accordance with the ingress protection (IP) requirements.
•
The DMX out of the last fixture is terminated with a 120 ohm resistor between pin 2 and 3 (according to the
RS485 standard), and the DMX out is properly sealed, in accordance with the ingress protection (IP) require
-
ments. Note that there can be connected a maximum of 32 fixtures to the same DMX link.
TRANSPORT HANDLING
Always use the supplied packaging or suitable flight case for transportation and storage. Never carry the fixture by
connected cables or wires.
The i-2 UVA may be installed in any orientation, on the ceiling or on a
wall surface.
When installed horizontally with a downward beam-angle, water,
moist, or grime can potentially pool in the fan wells. Under normal op
-
eration the moisture will evaporate.
In locations with high rainfall, you may wish to fabricate a rain shield
above the fixture, or modify the position and orientation of the fixture
to minimize pooling.
All SGM fixtures have locking points at the base for installation and rig
-
ging. In both standard and POI fixtures, the distance between the
points from center to center is always 106 mm. However, while the base
of the i-2 UVA standard fixture includes 1/4-turn fastener camlocks to
mount the omega brackets, the POI products come with M-10 nuts for
M-10 screws.
Always use the supplied omega bracket to rig a standard i-2 UVA. Lock
the bracket with the 1/4-turn fasteners.
RIGGING
106 mm
[ 4,2in ]
Ø 18 mm
[ 0,7in ]
Figure 1: Locking points