17
Product Version 1.0 | Revision A | Released 2022-2-21
Figure 12: POI Spanner
P-2 POI
B
A
A:
18 x 10W LEDs
B:
P-2 Tilt lock
C:
Cooling fan
D:
Control panel (POI n/a)
E:
OLED Display (POI n/a)
F:
DMX in and out
G:
Safety wire attachment point
H:
Dehumidifiers and GORE-TEX membranes
I:
Holes for Omega bracket / M-10 screws (x2)
J:
Power cable
K:
P-2 POI Tilt lock (POI only)
L:
LED indicator (POI only)
C
L
K
J
F
H
I
G
D
E
Figure 13: i-2 UVA POI LED indicator
WIRELESS DATA CONNECTION
LED INDICATOR BEHAVIOUR
In POI fixtures with wireless, it is necessary to pair the fixture
with a new transmitter (by default, the fixture is linked to the
SGM factory transmitter during the testing and QA process).
In order to do so, make sure the fixture is powered on before
taking the following steps:
STEP 1: Using a SGM magnetic spanner tool, place the magnet
close to the LED indicator, and wait for 3 seconds. The LED indi
-
cator will blink orange for 1-2 seconds, before switching to static
green again. The fixture can now be paired to a new transmitter.
STEP 2: Select “connect” or “link” on a wireless DMX transmitter.
The transmitter and the internal SGM receiver should now be
linked together.
Repeat the process to link the fixture to another transmitter.
To disconnect the fixture from the currently paired wireless transmitter, hold the magnet for 3 seconds over the LED
indicator. The LED indicator will blink orange for 1-2 seconds, switching later to green again. The fixture is now logged
off.
The LED indicator can have different colours and three possible
stages: static, flashing, or off.
•
Solid Orange: fixture is starting up.
•
Blinking Orange - Green: fixture is resetting its functions.
•
Blinking Green: reset has completed, no errors and no
wireless or wired DMX connection.
•
Solid Green: wireless/wired DMX connected.
•
Blinking Green - Orange - Red: fixture is resetting and er
-
ror(s) has occurred during reset.
•
Blinking Green - Red: reset has completed but error(s) oc
-
curred during reset.
•
Solid Red (3 seconds): hall sensor is activated. When acti
-
vated for longer than 3 seconds, wireless DMX connec
-
tion is logged off.
•
Off: fixture is off or LED indicator is set to auto-dimming
(set via RDM).Once configuration is complete, temporary
power and data can be disconnected.
MOUNTING
While the base of the standard products includes 1/4-turn fastener camlocks for omega brackets, the base of POI
products comes with M-10 nuts for M-10 screws. The M-10 screws are included in the package in the same amount as
the number of M-10 nuts of the base.
The i-2 UVA POI has two M-10 nuts at the base that can be used for installation and rigging. The SGM omega bracket
(not included) or a customized bracket is needed to install the fixture. Consider the dimensions below of the i-2 UVA
POI base for customized mounting brackets purposes.
The SGM POI omega bracket suited for M-10 holes can be ordered as an accessory. Contact your local SGM dealer for
further information on correct POI-rated mounting.
PLEASE NOTE! ENSURE THAT HARDWARE AND BRACKETS USED FOR MOUNTING IS A COMPATIBLE MATERIAL
WITH ALL COMPONENTS. GALVANIC REACTIONS CAN HAPPEN IN HIGHLY CORROSIVE ENVIRONMENTS. IM
-
PROPER HARDWARE AND SELECTION OF MOUNTING MATERIALS COULD VOID WARRANTY.