ISGM i-2UVA User Manual Download Page 15

15

Product Version 1.0 | Revision A | Released 2022-2-21

PLEASE NOTE! POI VERSION OF THE FIXTURE SHOULD BE PRESET WITH ANY CUSTOM PROGRAMMING 

BEFORE 

INSTALLATION

. ALTHOUGH IT IS POSSIBLE FOR MOST FUNCTIONS TO BE SET VIA RDM ONCE MOUNTED IN PO

-

SITION, IT IS EASIER TO DO CONFIGURATION AND ANY TROUBLESHOOTING BEFORE MOUNTING IS COMPLETE.

UNPACKING

Unpack the device and inspect it to ensure that it has not been damaged during transport.
The i-2 UVA is shipped with:

• 

1 x spanner with magnet (POI only).

• 

2 x M-10 screws (POI Only).

• 

Safety information leaflet.

APPLICATION CONSIDERATIONS

 The POI fixture is IP66-rated and designed for use in outdoor installations. This means that it is protected from:

• 

Dust, to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation.

• 

High pressure water jets from any direction. 

When selecting a location for the device, ensure that:

• 

It is situated away from public thoroughfares and protected from contact with people.

• 

It has adequate ventilation.

•  It is not immersed in water. 

CONNECTING TEMPORARY POWER

Connect to AC power using the supplied power cable. The 

fixture  must  be  grounded/earthed.  The  AC  power  supply 
must incorporate a fuse or circuit breaker for fault protec

-

tion. For temporary programming, a plug or terminals can 
be used.
The power cable color coding is shown on fig. 8:

• 

Connect the black wire to live

• 

Connect the white wire to neutral

• 

Connect the green/yellow wire to ground (earth)

Figure 9: Data wiring guide for setup

Figure 8: Connecting AC Power

The fixture must be grounded/

earthed and be able to be isolated 

from AC power. The AC power 

supply must incorporate a fuse or 

curcuit breaker for fault protection.

Color

Black

White

green/yellow

Conductor

live

neutral

ground (earth)

Symbol

or

L

N

Wire

SGM fixtures use the DMX 512 standard for communication.
STEP 1: Download and install the SGM RDM Addressing tool.

https://sgmlight.com/products/rdm-addressing-tool

 >

STEP 2: Connect the bare end data cable to the POI Up-load

-

er cable for POI fixtures.
STEP 3: Connect the USB uploader cable for POI fixtures to 
a  computer  with  a  USB  type-A  port.  When  addressing 
through USB powered DMX/RDM devices, ensure the DMX 
link is terminated, and keep all cables as short as possible.
STEP 4: Launch the SGM RDM addressing tool.Repeat Steps 
2-5 for more fixtures. Multiple fixtures can be addressed and 
configured. Contact your SGM representative for more in

-

formation on multiple fixture addressing.

CONNECTING TEMPORARY SIGNAL

Summary of Contents for i-2UVA

Page 1: ...USERMANUAL i 2UVA Product Version 1 0 Document Revision A Released 2022 2 21 ...

Page 2: ... subject to change without notice SGM and all affiliated companies disclaim liability for any injury damage direct or indirect loss conse quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document perwtaining to SGM services or SGM products are trad...

Page 3: ...3 Product Version 1 0 Revision A Released 2022 2 21 i 2 UVA POI All dimensions in millimetres and inches Drawing not to scale ...

Page 4: ...priority 13 Mounting bracket 14 INSTALLATION POI FIXTURE 14 Identification and terminology 15 Unpacking 15 Application considerations 15 Connecting temporary signal 16 Settings and Fixture Defaults 17 Wireless Data Connection 17 LED Indicator Behaviour 17 Mounting 18 Brackets 19 Flat Bracket attachment 19 Omega Bracket attachment 20 Universal Bracket attachment 21 Wall Bracket attachment 22 POI TI...

Page 5: ... ENGINE 29 Individual fixture settings 30 CONTROL MENU 31 RDM 31 Supported RDM functions 31 Sensors 32 ACCESSORIES 32 Accessory holder 32 Barndoors 32 Floorstand 33 MAINTENANCE 33 Anti glare shields 33 SGM Vacuum Test kit 34 Firmware Updates 35 Cleaning 35 Maintenance Schedule i 6 35 Maintenance Notes 36 TROUBLESHOOTING 37 FIXTURES AND ACCESSORIES 37 Ordering information 37 i 2 UVA accessories 37 ...

Page 6: ...way from objects to be illuminated Install only in accordance with applicable building codes Ensure a minimum clearance of 0 3 m 12 in around the cooling fans Do not paint cover or modify the device and do not filter or mask the light Keep all flammable materials well away from the device ALLOW THE DEVICE TO COOL FOR 15 MINUTES AFTER OPERATION BEFORE TOUCHING IT CAUTION EXTERIOR SURFACE TEMPERATUR...

Page 7: ...nd data cable leads are not intended for installation in per manently installed conduit or containment When installing fixtures in a permanent installa tion ensure cable leads are installed as a service loop to an appropriately rated junction box using suitable cable strain reliefs glands All installed fixtures must be securely mounted and service loop appropriately protected for installation loca...

Page 8: ...m received products This is subject to change without notice IDENTIFICATION AND TERMINOLOGY B A A 63 UV A LEDs B Tilt lock C Cooling fan D Control panel E OLED Display F DMX in and out G Safety wire attachment point H Dehumidifiers and GORE TEX membranes I Holes for Omega bracket J Power cable C J F H I G D E B ...

Page 9: ...n 2 and 3 according to the RS485 standard and the DMX out is properly sealed in accordance with the ingress protection IP require ments Note that there can be connected a maximum of 32 fixtures to the same DMX link TRANSPORT HANDLING Always use the supplied packaging or suitable flight case for transportation and storage Never carry the fixture by connected cables or wires The i 2 UVA may be insta...

Page 10: ...til they are fully attached to the base 4 Working from a stable platform hang the fixture on a truss or other structure Tighten the clamp bracket 5 Install a safety wire that can bear at least 10 times the weight of the fixture The safety wire attachment point is designed to fit a carabiner AISI316 grade 6 Verify that there are no combustible materials cables or surfaces to be illuminated within 0...

Page 11: ... encountered when tilting the fixture you might not have loosened the tilt screws enough CAUTION ALWAYS ALLOW THE FIXTURE TO COOL DOWN FOR 15 MINUTES AFTER OPERATION BEFORE HANDLING TILT LOCK WARNING ALWAYS SECURE AN ELEVATED FIXTURE WITH A SAFETY WIRE ALWAYS USE A SAFETY WIRE OF A GRADE AISI 316 STEEL MAKE SURE THE SLACK OF THE SAFETY WIRE IS AT A MINIMUM NEVER USE THE YOKE HANDLE FOR SECONDARY A...

Page 12: ...CTRICAL DIMMER SYSTEM AS DOING SO MAY CAUSE DAMAGE CONNECTING A WIRELESS TRANSMITTER The i 2 UVA is designed to look for wireless transmitters in connect state when this option is not yet enabled The fixture comes tested for wireless functionality from the factory therefore the beginning of the pairing process is to disconnect from the factory wireless DMX transceiver To connect the i 2 UVA to a w...

Page 13: ...while operating and protect delicate surfaces from scratching If a more secure mounting is required remove the four rubber push in bumpers from the mounting bracket Then securely fasten the fix ture on the ground wall by using 4 x 6 mm 1 4 in fasteners on the resulting holes PLEASE NOTE THE INCLUDED MOUNTING BRACKET IS NOT IN TENDED FOR PERMANENT OUTDOOR INSTALLATION REFER TO POI SECTION FOR OPTIO...

Page 14: ...trations might vary from received products This is subject to change without notice A 63 UV A LEDs B POI Tilt lock C Cooling fan D LED indicator POI only E DMX in and out F Safety wire attachment point G Dehumidifiers and GORE TEX membranes H Holes for Omega bracket M 10 screws x2 I Power cable B A C D I E G H F B ...

Page 15: ...OWER Connect to AC power using the supplied power cable The fixture must be grounded earthed The AC power supply must incorporate a fuse or circuit breaker for fault protec tion For temporary programming a plug or terminals can be used The power cable color coding is shown on fig 8 Connect the black wire to live Connect the white wire to neutral Connect the green yellow wire to ground earth Figure...

Page 16: ...reen light to light up on the fixture If the green light does not appear cycle power or refer to troubleshooting STEP 2 Select the standard settings tab and enter a DMX address and a personality mode of operation Look for the LED indicator to blink to confirm the settings change DMX modes for POI are the same as for the standard Visit www sgmlight com to see all DMX charts available under the resp...

Page 17: ...linking Green reset has completed no errors and no wireless or wired DMX connection Solid Green wireless wired DMX connected Blinking Green Orange Red fixture is resetting and er ror s has occurred during reset Blinking Green Red reset has completed but error s oc curred during reset Solid Red 3 seconds hall sensor is activated When acti vated for longer than 3 seconds wireless DMX connec tion is ...

Page 18: ...ct Version 1 0 Revision A Released 2022 2 21 Flat bracket Omega bracket Wall mount bracket Figure 14 i 2 UVA POI base with dimensions Universal bracket BRACKETS There are four bracket choices available from SGM ...

Page 19: ...KET ATTACHMENT M10 Countersunk Bolts Flat Bracket 8mm or smaller screw or bolt to structure 8mm or smaller screw or bolt to structure 13mm 0 5in hole diameter for attachment point M10 Stainless Steel Bolts POI Omega Bracket Fixture OMEGA BRACKET ATTACHMENT Fixture ...

Page 20: ...Fixture UNIVERSAL BRACKET ATTACHMENT POI Universal Bracket Using a bolt through this slot the fix ture will rotate around its center point always use 2 bolts with washers Using a bolt through this slot the fixture will rotate around its center point always use 2 bolts with washers ...

Page 21: ... and level the bracket Then tighten to the surface Using the holes shown use appropriately rated fasteners for both location and surface material and construction Fasten ers should be no larger than M6 Wall Attachment Slots FIxture Attachment Slots Alignment Slots Use the supplied countersunk M10 bolts to secure the fixture to the bracket Ensure cabling is not pinched or trapped when mounting fixt...

Page 22: ...sted by using the large pig nose key provided in the spanner To adjust the tilt angle in i 2 UVA POI take the following steps Use the spanner and turn both tilt lock screws one on each side counter clockwise by using the large pig nose key Screws are loosened by turning coun ter clockwise Tilt the fixture to the angle desired and hold it Lock the position by tightening the tilt lock screws clockwi...

Page 23: ...out the SGM POI DMX cable For permanent installations have a qualified electrician wire the mains cable directly to a suitable branch circuit For a temporary installation the mains cable may be fitted with a grounded connector intended for exterior use PLEASE NOTE Cat5e compliant cable is suitable for the transmission of DMX 512 with RDM Up to 32 fixtures can be on the same DMX link Additional fix...

Page 24: ... indicator and wait for 3 sec onds The LED indicator will blink orange for 1 2 seconds before switching to static green again The fixture can now be paired to a new transmitter STEP 2 Select connect or link on a wireless DMX transmitter The transmitter and the internal SGM receiver should now be linked together Repeat the process to link the fixture to another transmitter To disconnect the fixture...

Page 25: ...te list of the menu and all commands available are listed in Con trol menu Before turning on the i 2 UVA make sure the power cable is properly connected When the fixture is powered on it boots and resets before displaying the selected operating mode and DMX start address Navigate through the menus and options using the arrow buttons and select items using the ENTER button Lorem ipsum dolor sit 6CH...

Page 26: ...erational mode B DMX address C External data indicator DMX D External data protocol next available DMX address Figure 19 i 2 Display EXTERNAL DATA PROTOCOL D Shows the external data protocol CRMX or DMX When DMX is displayed the fixture responds to data received through cabled DMX When CRMX is displayed the fixture responds to data received through wireless DMX The next available DMX address will ...

Page 27: ...re uses the first 2 DMX channels including channel 101 the next available channel is 103 101 2 103 If two or more i 2 UVA have the same DMX start address they will behave identically Incorrect settings will result in unpredictable responses from the lighting controller Address sharing can be useful for diagnostic purposes and sym metrical control SET EDIT DMX ADDRESS The DMX address is shown on th...

Page 28: ...om one color to the next and a wait static time of up to 120 minutes and 59 seconds To define a stand alone program press ENTER MANUAL EDITOR The standalone mode of the fixture s startup is enabled by selecting ENTER SETTINGS STARTUP MODE SELECT STARTUP MODE STANDALONE To select the fixture s startup program press ENTER SETTINGS STARTUP MODE STARTUP PROGRAM The chosen program will run its length c...

Page 29: ...IP DISPLAY or press the up and down buttons on the control panel at the same time Setting the OLED display saver POI n a By default the OLED display dims down after a short period when the control panel is not in use The display can also be set to turn off completely Pressing any key will turn on the display or restore it to normal brightness To configure the display settings press ENTER SETTINGS ...

Page 30: ...cted or not Battery PCT Displays battery level Charging Displays whether the battery is charging or not Battery VDC Displays battery voltage Wireless Signal Displays wireless signal strength Wireless Paired Displays wireless connection status POWER ON TIME Displays fixture s total power on time LED ON TIME Displays LED s total power on time ERRORS Displays error codes SETTINGS STARTUP MODE SELECT ...

Page 31: ...rameters See the tables below for supported RDM functions PLEASE NOTE THE RDM CONTROLLER COMMUNICATES WITH THE FIXTURES TO SHOW ONLY THE AVAILABLE OPTIONS FOR EACH RDM FUNCTION TABLES ARE SUBJECT TO CHANGE WITHOUT NOTICE SENSORS RDM enables various sensor readouts for remote device monitoring See the table below for sensors and sensor types PLEASE NOTE THE RDM CONTROLLER COMMUNICATES WITH THE FIXT...

Page 32: ...an extra control when cutting the light by extending and adjusting the width of the side flaps The barndoors are designed and intended to be mounted on the fix ture without the use of any tools Simply attach the accessory holder to the fixture and slide the barndoors from one side Secure the barndoors with the help of the swivel arm on the side of the accesso ry holder and the locking knob attache...

Page 33: ...le is also used for controlling the DMX val ues channel by channel through the Firmware Uploader Tool soft ware available for download at www sgmlight com Figure 28 SGM Vacuum Test Kit Figure 29 SGM Uploader Cable MAINTENANCE Figure 26 i 2 UVA Anti glare Shields Figure 27 i 2 UVA Anti glare Shields ANTI GLARE SHIELDS The i 2 UVA features two different types of optional anti glare shields Full anti...

Page 34: ...ge on the SGM website Connect either Std or POI uploader cable depending on which is more suitable for the installation Launch SGM Firmware Tool on a windows PC Click File then Open and navigate to the firmware file needed select it and click Open The firmware is now loaded in the uploader click Upload Firmware The fixture will now update and reboot The Firmware Tool software offers a simple DMX c...

Page 35: ...ning as they can cause damage to hard ware cables and connectors The level of cleaning required will vary greatly depending on the operating environment and installation Therefore it is recommended to do frequent check ups the first few weeks of operation to see how often cleaning is necessary MAINTENANCE SCHEDULE i 6 MAINTENANCE NOTES 1 In rough service environments such as with dust or fog haze ...

Page 36: ...s Fixture operates irregularly abnormally DMX cable polarization is inverted pin 2 3 Reverse the polarity DMX link is not terminated Install a XLR 120ohm DMX termination at the end of the DMX link Corrupted DMX cable Replace or repair defective cables and or connections The fixture operates an internal program Go to MENU MANUAL STOP PROGRAM A corrupted fixture generates noise disruptions on the DM...

Page 37: ...3062011 USB POI uploader cable P N 83062067 Floorstand for i 2 P 2 Q 2 P N 83060613 Accessory holder i 2 P 2 Series BL P N 83061127 Barndoor 4 way i 2 P 2 Q 2 Series BL P N 83061129 Barndoor 8 way i 2 P 2 Q 2 Series BL P N 83061130 Color frame i 2 P 2 Q 2 Series P N 83061131 Half anti glare shield small BL P N 83061161 Full anti glare shield small BL P N 83061164 Honeycomb for i 2 UVA P N 36800040...

Page 38: ...irective Conforms to 2014 30 EU EMC Directive Conforms to 2011 65 EU RoHS2 Directive Pending ANSI UL Std 1573 Pending CSA Std C22 2 No 166 The information in this document is subject to chance without notice For the latest information visit www sgmlight com APPROVALS AND CERTIFICATIONS RoHS ...

Page 39: ...39 Product Version 1 0 Revision A Released 2022 2 21 USER NOTES ...

Page 40: ...40 Product Version 1 0 Revision A Released 2022 2 21 SGM LIGHT A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com ...

Reviews: