12
Product Version 1.0 | Revision A | Released 2022-2-21
CONNECTING POWER
The power cable color coding is given in figure 6:
•
Connect the black wire to live
•
Connect the white wire to neutral
•
Connect the green/yellow wire to ground (earth)
For a temporary outdoor installation the mains cable must be fitted with a grounded connector intended for exterior
use.
For permanent installations, have a qualified electrician wire the mains cable directly to a suitable branch circuit. Any
cable management must have an appropriate (IP) rating suitable for the location. Always use a junction box with a
proper IP class suitable for the environment.
After connecting the i-2 UVA to power, run the on-board test by selecting the option TEST→ SELF-TEST in the menu to
ensure that the fixture and each LED are functioning correctly. POI versions have to be tested through RDM.
PLEASE NOTE!
THE PROTECTIVE CAPS MUST BE SECURELY MOUNTED ON ANY UNUSED CONNECTORS, IN ORDER TO MAIN
-
TAIN THE INGRESS PROTECTION (IP RATING).
CAUTION!
DO NOT OPEN THE FIXTURE TO REPLACE THE SUPPLIED POWER CABLE.
DO NOT CONNECT THE FIXTURE TO AN ELECTRICAL DIMMER SYSTEM, AS DOING SO MAY
CAUSE DAMAGE.
CONNECTING A WIRELESS TRANSMITTER
The i-2 UVA is designed to look for wireless transmitters in ‘connect’ state when this option is not yet enabled. The
fixture comes tested for wireless functionality from the factory, therefore the beginning of the pairing process is to
disconnect from the factory wireless DMX transceiver.
To connect the i-2 UVA to a wireless transmitter:
Log off the currently paired wireless transmitter. Go to SETTINGS → WIRELESS DMX → LOG OFF in the menu. Fixture
confirms logged off.
1. Press the connect button on the wireless transmitter.
2.
Confirm that the fixture has paired with the wireless transmitter.
PLEASE NOTE! FOR POI VERSIONS, REFER TO “WIRELESS DATA CONNECTION”.
SIGNAL PRIORITY
The i-2 UVA can be paired to an active wireless transmitter simultaneously when connected to a cabled DMX. The
fixture will prioritize cabled DMX over wireless DMX.
The active input type is displayed under the wireless signal strength indicator. The signal strength can be also checked
via RDM data by using an external RDM device.
PLEASE NOTE! IN POI VERSION WITH WIRELESS, THE DMX SIGNAL STRENGTH IS CHECKED THROUGH RDM.
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
Figure 6: Connecting AC Power