Product Version 1.0 | Revision A | Released 2022-2-21
Fasten a safety wire (not shown) between the load-bearing support
structure and the safety wire attachment point on the device.
•
The safety cable (not included in the package) must:
•
Bear at least 10 times the weight of the device (SWL).
•
Have a minimum gauge of 4 mm.
•
Have a maximum length (free fall) = 30 cm (12 in.).
Figure 4: Safety wire attachment point
The fixture can be tilted from 0° - 180°.
To adjust the tilt angle in standard versions:
1. Loosen the two tilt screws (one on each side) by turning them
counter-clockwise.
2.
Tilt the fixture to the angle desired and hold it.
3.
Lock the position by re-tightening both tilt lock screws clock
-
wise.
If resistance is encountered when tilting the fixture, you might not
have loosened the tilt screws enough.
CAUTION!
ALWAYS ALLOW THE FIXTURE TO COOL DOWN FOR 15
MINUTES AFTER OPERATION BEFORE HANDLING.
TILT LOCK
WARNING! ALWAYS SECURE AN ELEVATED FIXTURE WITH A SAFETY
WIRE. ALWAYS USE A SAFETY WIRE OF A GRADE AISI 316 STEEL.MAKE
SURE THE SLACK OF THE SAFETY WIRE IS AT A MINIMUM.NEVER USE THE
YOKE/HANDLE FOR SECONDARY ATTACHMENT.
POWER REQUIREMENTS
The i-2
can operate on any 100–277 V, 50/60 Hz AC mains power supply, and draws a maximum of 190W.
Connect the fixture to AC power by installing a power connector to the bare end side of the supplied power cable.
Connect the powercon twist-lock connector side to the fixture. The fixture must be grounded/earthed and be able to
be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
Figure 5:
i-6
Standard tilt lock