10
Product Version 1.0 | Revision A | Released 2022-2-21
RIGGING PROCESS USING SGM OMEGA BRACKETS
Start the standard rigging process by blocking the lower
working area, and make sure the work is performed from
a stable platform.
1.
Check that the clamp/bracket is undamaged and
can bear at least 10 times the weight of the fixture. Check
that the structure can bear at least 10 times the weight of
all installed fixtures, lamps, cables etc.
2.
Bolt the clamp/bracket securely to the omega brack
-
et with a M12/ ½ bolt (min. grade 8.8) and a lock nut.
3.
Align the omega bracket with the i-2 UVA base. For
standard omega bracket, insert the fasteners into the i-2
UVA base bracket, and turn both levers 1/4-turn clockwise
to lock. When using the POI omega bracket, insert the in
-
cluded M-10 screws through the bracket holes and tight
-
en with a M-10 key until they are fully attached to the base.
4.
Working from a stable platform, hang the fixture on
a truss or other structure. Tighten the clamp/bracket.
5.
Install a safety wire that can bear at least 10 times
the weight of the fixture. The safety wire attachment
point is designed to fit a carabiner AISI316 grade.
6.
Verify that there are no combustible materials, cables, or surfaces to be illuminated within 0.3 m (12 in.) of the
fixture.
7.
Check that there is no risk of the head/yoke colliding with other fixtures or structures.
Figure 2: Dimensions for i-2 UVA base locking points
PLEASE NOTE! THE 1/4-TURN FASTENERS ARE ONLY LOCKED WHEN TURNED FULLY CLOCKWISE.
DEPENDING ON THE STRUCTURE, PLEASE USE APPROPRIATE AND SECURE METHODS FOR MOUNTING THE
OMEGA BRACKETS.
PLEASE NOTE! THE SUPPLIED OMEGA BRACKET IS NOT RATED FOR PERMANENT OUTDOOR INSTALLATION
(POI). FOR MORE INFORMATION, SEE IN ”POI VERSION (PERMANENT OUTDOOR INSTALLATION)” .
94mm
3,701in
106mm
4,173in
45mm 1,772in
A
∅
18mm
0,709in
∅
14mm
0,551in
DETAIL A
SCALE 1 : 1
Figure 3: Installing the i-2 UVA