INSTALLATION GUIDE

1. TECHNICAL SPECIFICATIONS

Frame, wall mounting and desktop reader/writer units for F9000 keys.

PRODUCT:

- Cylinder hole for F9000 key insertion.
- RS485 communication interface.
- Power supply: by Atlas.
- Power consumption: 1W.
- Multicolor signaling LEDs (green, blue, red) and acoustic buzzer.

FEATURES:

- Operating temperature: -10°C ÷ +50°C (internal version).
- Operating temperature: -25°C ÷ +50°C (external IP55 version).
- Storage temperature: -25°C ÷ +75°C.

ENVINRONMENTAL CHARACTERISTICS:

2. MODELS & VERSIONS

Wall fixings not provided in 
the kit. The installator must 
choose the most suitable 
fixings according to the wall 
type and material.

- Desktop version: 120 x 111 x 82 mm
- Frame Mounting 503 version: 120 x 82 x 55 mm
- Frame mounting GIRA version: 80 x 80 x 50 mm
- Wall Munting Vimar version: 120 x 88 x 55 mm
- Wall Munting Vimar IP55 version: 100 x 83 x 65 mm

DIMENSIONS (LxDxH):

IP5

5

VIM

A

R

Desktop Reader

(Vimar Idea plastic box)

Frame Mounting Reader

(Vimar Idea frame & 

503 box compatible)

Frame Mounting GIRA

(GIRA frame & box 

compatible)

Wall Mounting Reader

(Vimar Idea plastic box)

Wall Mounting IP55 Reader

(Vimar Idea IP55 plastic box)

3. WARNINGS

Read this manual prior to use the device in order to ensure a safe and proper use.

Preserve this manual as future reference.

The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

The instructions should be carefully followed during the use of the product. These instructions should be 
passed on by the installer to the user.

No modifications of any kind are permitted, except for those described in these instructions.

The product must be destined only for the use for which it is expressly designed and therefore as a reader and 
writer unit for civil and industrial locations. Any other use is considered improper and dangerous.

4. ELECTRICAL CONNECTIONS

TX/RX 485 (A)
TX/RX 485 (B)

(10 

÷

 24 Vdc)

(GND)

F9000 Reader

connector (RS485)

- Wiring cable not included in the kit.
- Recommended cable: Ethernet cable FTP AWG24  
  CAT5E (and above or equivalent data cable).
- Min/max cross-section of the wires: 0.20÷1.5mm

2

  

  (24÷15AWG).
- Min/max cable diameter: 3÷7mm
- Max length: up to 500mt

R

5. ELECTRICAL CONNECTIONS TO ATLAS

R = 120 ohm - 1/4 W

Supplied with the reader

ATLAS DIN 

ATLAS STANDARD (STD)
ATLAS PLUS 

CH1 

4

3

2

1

(GND)

CH2 

4

3

2

1

5
6

CH2 

4

3

2

1

(GND)

CH1 

4

3

2

1

(GND)

6. ELECTRICAL CONNECTIONS EXAMPLE: TO ATLAS BY ETHERNET CABLE

Ethernet cable

FTP AWG24 CAT5E

(Max length 500mt)

R

4

3

2

1

ATLAS PLUS/STD CH1 (J5)
ATLAS DIN CH1 and CH2

R

A

B

F9000 Reader

connector (RS485)

Maximum Ethernet cable length between Atlas and F9000 Reader: 500mt.

Required Atlas power supply: 24Vdc.

Resistance value: 120 ohm (1/4W) on both Atlas and F9000 Reader sides.

Connect the ethernet cable shield to the Atlas GND connector only if Atlas NOT connected to ground.

(GND)

R = 120 ohm (1/4 W)

For more information about Atlas and its connectors, refer ot the 

Atlas Installation Guide 

avalable at:

app.iseo.com

.

  6.1 ELECTRICAL CONNECTIONS EXAMPLE: TO ATLAS CH2 BY ETHERNET CABLE

Ethernet cable

FTP AWG24 CAT5E

(Max length 500mt)

R

4

3

2

1

R

A

B

(GND)

R = 120 ohm (1/4 W)

ATLAS PLUS/STD CH2 (J11)
and CH1 (J5)

4

3

2

1

(GND)

4

3

2

1

5
6

CH1 

CH2 

See warnings at box 6.

F9000 Reader

connector (RS485)

Recommended capacitance conductor/conductor < 100pF/m.
Recommended conductors electrical resistance max 90 ohm/Km.

Ethernet cable FTP AWG24 CAT5E (and above).

A

B

A

B

https://www.iseo.com/it/it/download

Summary of Contents for Zero1 F9000

Page 1: ...t These instructions should be passed on by the installer to the user No modifications of any kind are permitted except for those described in these instructions The product must be destined only for the use for which it is expressly designed and therefore as a reader and writer unit for civil and industrial locations Any other use is considered improper and dangerous 4 ELECTRICAL CONNECTIONS TX R...

Page 2: ...t cable shield to the Atlas GND connector only if Atlas NOT connected to ground For more information about Atlas and its connectors refer ot the Atlas Installation Guide avalable at app iseo com Recommended capacitance conductor conductor 100pF m Recommended conductors electrical resistance max 90 ohm Km R R R R Shielded alarm cable good quality 4 x 0 35mm 22AWG A B A B 8 INSTALLATION EXAMPLE DESK...

Page 3: ... ISEO Le istruzioni devono essere seguite attentamente durante l uso del prodotto Queste istruzioni dovrebbero essere passate dall installatore all utente Nessuna modifica di alcun tipo è consentita ad eccezione di quelle descritte in queste istruzioni Il prodotto deve essere destinato esclusivamente all uso per il quale è espressamente progettato e quindi come unità di lettura e scrittura per amb...

Page 4: ... al connettore Atlas GND solo se Atlas NON è collegato a terra Per ulteriori informazioni su Atlas e sui suoi connettori consultare la Guida all installazione di Atlas disponibile all indirizzo app iseo com Conduttore capacitativo consigliato 100 pF m Conduttore elettrico consigliato max resistenza 90 ohm Km R R R R Cavo di allarme schermato di buona qualità 4 x 0 35mm 22AWG A B A B 8 ESEMPIO DI I...

Reviews: