Iseo X1R Smart Installation Manual Download Page 8

10. ELECTRICAL CONNECTIONS

OPEN

internal module

external module

remote opening command
NA (not supplied).

8÷30Vdc/ac

To know more about the 
connections of the 8 pins 
multifunction cable and X1R 
Smart as actuator, refer to 
the user manual, available 
at link “

app.iseo.com

”. 

keyboard and RFID reader cable

Bluetooth radio cable

8 pins multifunction cable 

male connector

(back side/wires view)

8 7 6 5
4 3 2 1

Color

Green
Orange
Black
Brown
Yellow
White
Red
Blue

Description

 

1
2
3
4
5
6

8

7

Relay common contact*
Relay normally open contact*

   Negative power supply

Opening command 

8÷30Vdc/ac

Relay normally closed contact*
Not used
+ Positive power supply 8÷30Vdc/30W 

MAX

Opening command 8÷30Vdc/ac

brown (4)

blue (8)

alkaline

* Relay: 

30Vdc/Vac - 1A 

MAX

Only to use X1R Smart

 without external reader and keyboard

 (functioning as an actuator): place the 

jumper, available in the package, in the PINs 1 and 2 of connector JP1. Take care the jumper is perfectly 
and securely fitted into the PINs.

Non contractual document. Subject to change. Cod. 

6000006990013.3

 - 23/08/2017

X1R Smart installation guide (UK)

 - © 2017  Iseo Serrature S.p.a. - www.iseo.com

Connettore JP1: 

PIN 1 e 2 chiusi dal jumper

Summary of Contents for X1R Smart

Page 1: ...ous Do not work on the door with the lock installed in order to prevent wood or metal residue getting into the lock Distance between striking plate and latch tip completely in from both motor or key must be between 2 and 3mm Handle must not have any friction during the return phase Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain subjected to traction...

Page 2: ...42 max 38 max 0min 33max 15 3 n 4 x 6 37 37 37 30 262 40 14 2 39 2 28 28 28 28 410 35 164 65 n 3 x M5 L 3 8 12 13 21 31 33 262 108 n 2 x M6 To find all available versions and related codes check the IseoZero1 catalogue Add the plug indicated in the picture below only for Single Action version 2 VERSIONS ...

Page 3: ...2 Only if latch version 13mm Max latch projection adjustment 6mm LATCH ADJUSTMENT 4 DOOR CONTACTS REVERSIBILITY AND ADJUSTMENT It is forbidden to lubricate the door contacts It is possible to use ethyl alcohol to clean the door contacts 1 2 ...

Page 4: ...oes not remain engaged which will cause the motor to rotate in neutral 1 2 6 DOOR CLOSED CONTACTS FIXING 21 5 43 54 3 5 mm TOP BOTTOM black red In the case of power supply via door contacts use an external power supply 8 30Vdc 30W Low voltage contacts Do not touch with your fingers Do not connect to power supply that exceed the indicated ones Respect power polarity It is forbidden to lubricate the...

Page 5: ...l panel 50 50 25 25 50 33 0 max 93 Make a 50 mm diam hole only in the external panel in order to install the external cylinder protection Make a 25x25 mm slot in the outside panel and plate to allow the external module cable to pass through Keyboard with RFID reader Only RFID reader ...

Page 6: ...7 1 INTERNAL SIDE DOOR ASSEMBLING Internal control module assembling on the internal panel 50 50 200 max 93 Internal control module is not necessary if Single Action version Opening and closing buttons ...

Page 7: ...rd version 3 Alkaline batteries 4 Power supply 8 30Vdc 30W 5 Cable gland 6 Bipolar cable connection for remote opening command 7 Bipolar connection cable kit 8 Multifunction connection cable 8 pins 9 BATTERY HOLDER HOUSING 84 38 110 min 250 Before powering the x1R Smart make sure the red and black wires are intact and the battery housing connector does not come into contact with the door frame in ...

Page 8: ...act Relay normally open contact Negative power supply Opening command 8 30Vdc ac Relay normally closed contact Not used Positive power supply 8 30Vdc 30W MAX Opening command 8 30Vdc ac brown 4 blue 8 alkaline Relay 30Vdc Vac 1A MAX Only to use X1R Smart without external reader and keyboard functioning as an actuator place the jumper available in the package in the PINs 1 and 2 of connector JP1 Tak...

Reviews: